background image

EN

10

Operating manual – radial fan TFV PRO 1

Declaration of conformity

EC Declaration of Conformity

in accordance with EC Machinery Directive 2006/42/EC

Trotec GmbH & Co. KG

Grebbener Straße 7

D-52525 Heinsberg

herewith  declares,  that  due  to  its  design  and  construction,  and  in  the  version  introduced  by  us,  the
following machinery conforms with the relevant fundamental requirements of the listed EC directives.

Important note:

In  case  of  improper  use,  installation,  maintenance  etc.  or  unauthorized  changes  of  the  factory-supplied
device version, this declaration loses its legal validity.

Device version:

Radial fan

Series:

Year of manufacture:

as of 06/2016

Applicable regulations:

Applied harmonised standards:

Producer and authorised representative of the technical documentation:

Trotec GmbH & Co. KG

Machinery Directive
Low Voltage Directive
EMC Directive

Grebbener Straße 7

D-52525 Heinsberg

+49 2452 962-400

+49 2452 962-200

[email protected]

   

 

Heinsberg,

Managing Director:
Detlef von der Lieck

TFV PRO 1

2006/95/EG
2014/35/EU
2014/30/EU

01.06.2016

(Translation of the original)

Содержание TFV PRO 1

Страница 1: ...TRT BA TFVPRO1 TC 002 EN TFV PRO 1 EN OPERATING MANUAL RADIAL FAN ...

Страница 2: ...n marked with this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed The current version of the operating manual can be found at TFV PRO 1 http hub trotec com id 39587 Legal notice This release replaces all previous versions No part of this publication may be reproduced without writ...

Страница 3: ... accessories and connection parts for possible damage prior to every use of the device Do not use any defective devices or device parts Ensure that all electric cables outside of the device are protected from damage e g caused by animals Never use the device if electric cables or the power connection are damaged The electrical connection must correspond to the specifications in chapter Technical d...

Страница 4: ...ce and result in damage to the device Note Do not use abrasive cleaners or solvents to clean the device Behaviour in the event of an emergency 1 In an emergency disconnect the device from the mains feed in Switch the device off and disconnect it from the mains 2 Remove persons from the danger area 3 Do not reconnect a defective device to the mains Information about the device Device description Th...

Страница 5: ... from invasive dust if necessary stackable up to 5 devices on top of one another Assembly and installation Scope of delivery Device Air filter Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up Place the dev...

Страница 6: ... and result in damage to the device Make sure that the air filter is installed before switching the device on The air filter must be seated in the lower guide rail Mounting an adapter plate optional You can mount optionally available adapter plates for 3 8 or 12 hose connectors to the device The adapter plate for 3 connectors is used as an example in the following The adapter plates with 8 or 12 c...

Страница 7: ...ins plug into a properly secured mains socket Operation Operating elements h kWh 21 20 22 23 No Designation 20 Fan speed rotary control 21 Power button 22 Kilowatt hours counter with LED 23 Operating hours counter Switching the device on 1 Press the power button 21 ð The power button 21 lights up 2 Turn the rotary control 20 to the right until the fan starts running Info You can read the number of...

Страница 8: ... defective If so contact Trotec or a specialist electrical company Check the air filter for dirt If necessary clean or replace the air filter The motor or fan is noisy or runs unevenly The fan is soiled Clean the fan according to the Maintenance chapter The fan is damaged If so contact Trotec or a specialist electrical company The motor bearing might be damaged If so contact Trotec or a specialist...

Страница 9: ...ing by loosening the attachment screws 2 Clean the inside of the housing and the fan blades carefully with a slightly damp cloth 3 Allow the fan to dry 4 Reattach the upper cover to the housing Make sure that the cover is positioned correctly and that the seals fit exactly and are not damaged 5 Screw the upper cover to the housing again Cleaning the air filter The air filter should be cleaned prio...

Страница 10: ... S1 2 1 L 5 4 N 10K R1 h kWh P1 LinLout N M1 DC out E1 GND L1 N PE Aderfarben wire colors sw schwarz black rt rot red ge gelb yellow gnge gruen gelb green yellow Gehäuse housing 230V AC 50 60Hz HW66 Kombizähler L in L out N BL GE RT SW BL GNGE bl blau blue Disposal In the European Union electronic equipment must not be treated as domestic waste but must be disposed of professionally in accordance ...

Страница 11: ... of improper use installation maintenance etc or unauthorized changes of the factory supplied device version this declaration loses its legal validity Device version Radial fan Series Year of manufacture as of 06 2016 Applicable regulations Applied harmonised standards Producer and authorised representative of the technical documentation Trotec GmbH Co KG Machinery Directive Low Voltage Directive ...

Страница 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: