Страница 1: ...TRT BA TFC25E TC220421TTRT03 001 EN TFC 25 E EN OPERATING MANUAL FAN HEATER EN This product is only suitable for well insulated spaces or occasional use ...
Страница 2: ...nual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental cap...
Страница 3: ... device and all combustible materials such as textiles curtains beds and sofas Make sure that the air inlet and outlet are not obstructed Make sure that the suction side is kept free of dirt and loose objects Do not place the device on combustible ground Only use original spare parts for otherwise safe and functional operation cannot be ensured Allow the device to cool down before transport and or...
Страница 4: ...lectrical components must only be carried out by an authorised specialist company Warning of electrical voltage Before any work on the device remove the mains plug from the mains socket Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable out of the mains socket Warning of electrical voltage Risk of electric shock The device must not come into c...
Страница 5: ...es the device off when it is inclined by a few degrees out of its vertical position The tilt protection is also tripped when lifting the device a little e g for transport during operation The device can again be used as usual only a few seconds after placing it back in vertical position and on solid ground Information about the device Device description The ceramic heater serves to generate and di...
Страница 6: ... pulling the power cable out of the mains socket Do not use the power cable to drag the device Allow the device to cool down sufficiently Storage Before storing the device proceed as follows Hold onto the mains plug while pulling the power cable out of the mains socket Allow the device to cool down sufficiently When the device is not being used observe the following storage conditions Store the de...
Страница 7: ...t observed Observe the Installation section in the Assembly and start up chapter and the technical data in the Technical annex chapter Foot assembly 1 Place the device on its side 2 Attach the foot 4 to the device from below so that the clips 9 of the device engage into the recesses of the foot 9 4 3 Fold down the clips 9 so that the foot is locked 9 4 4 Check the foot 4 for tight fit 5 Set the de...
Страница 8: ...mote control Warning of electrical voltage Do not touch the battery compartment with wet or damp hands Note Do not use rechargeable batteries Observe the Technical data for start up 1 Press the upper part on the back of the remote control and pull the battery cover off the remote control 2 Insert a CR 2032 battery into the battery compartment adhering to the correct polarity 3 Slide the battery co...
Страница 9: ...tion I ð The device is now in standby mode 2 Press the On Off button 21 ð An acoustic signal is emitted ð The target temperature set most recently will be indicated on the display ð At initial start up the target temperature is preset to 25 C ð The device is switched on Setting the operating mode The device comes with the following operating modes Heating function Cold air operation Eco mode Heati...
Страница 10: ...ce will switch to Standby after the predefined time Notes regarding automatic switch off Manually switching the device off disables the automatic switch off function If you select the set number of hours of 0 the timer will be off Note The device must not be left unattended in a freely accessible room with an activated timer Memory function Info In the Standby mode the device memorises the room te...
Страница 11: ...it for 10 minutes before restarting the device If the device is not starting have the electrics checked by a specialist company or by Trotec The fan is not running Check whether the device is switched on Check the power connection Check the power cable and mains plug for damages The fan motor might be defective Have a defective fan motor replaced by a specialist electrical company The air current ...
Страница 12: ...ents alcohol based or abrasive cleaners to dampen the cloth Wipe the housing dry after cleaning Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist electrical company or by Trotec 5 Put t...
Страница 13: ...Level 1 level 2 1800 W 2500 W Operating range 20 C to 35 C Mains connection 220 240 V 50 Hz Power consumption max 2500 kW Type of protection IPX0 Protection class II Plug type CEE 7 17 Cable length 1 6 m Sound pressure level 50 dB Dimensions depth x width x height 260 x 260 x 800 mm Minimum distance to walls and other objects A top B rear C side D front 100 cm 100 cm 100 cm 100 cm Weight 3 5 kg Re...
Страница 14: ... and or outdoor temperature feedback NO Fan assisted heat output NO Type of heat output room temperature control Single stage heat output no room temperature control NO Two or more manual stages no room temperature control NO With mechanic thermostat room temperature control NO With electronic room temperature control YES With electronic room temperature control plus day timer NO With electronic r...
Страница 15: ...d for your country The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment In the European Union batteries and accumulators must not be treate...
Страница 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...