Operating Manual – Electrical Fan Heater TDS 30
3
Warning!
Read and observe the warnings and instructions in
the Safety chapter. Abide by it to ensure a safe
operation of this device.
Check whether the power cable is intact. If the power cable is
damaged, it must be replaced by the manufacturer, his customer
service or similarly qualified personnel. Make sure that the
electrical properties of the socket correspond to the values
specified in the operating manual or on the nameplate. Place the
device on dry, even ground. Make sure that the device cannot
come into contact with moisture or water at this installation site.
Switch-on
1. Connect the power cable to the mains.
2. Turn the switch to the desired position:
Regulation of the room thermostat
Adjust the room temperature by turning the
rotary switch of the room thermostat.
When the set value is exceeded, the heating
switches off while the fan keeps running.
Switch-off
1. Keep the fan running for 3 minutes, before switching the
device off.
2. Turn the switch into position
0
.
3. Disconnect the power cable from the mains.
Overheating protection
The device is provided with a safety thermostat, which is
activated by overheating of the device. In such an event the
device switches off automatically.
When the safety thermostat is activated, allow the device to cool
down. Only then start to look for a cause of the overheating.
Should the problem continue to exist, please contact the
customer service.
1)
If at a relative humidity of 80 % the storage temperature amounts to 40 °C,
the device can be stored for 96 h at most under these conditions. If in the stated
circumstances the device is stored for more than 96 hours, additional protective
measures against moisture are to be taken.
Circuit diagram
Operation
1. Ventilation
2. Heating operation 3. Heating operation
Stage I
Stage II
Technical data
Parameter
Value
Model:
TDS 30
Air flow rate, max.:
458 m
3
/h
Heating capacity, max.:
5500 W
Input voltage:
3~/PE 400 V / 50 Hz
Mains connection:
CEE plug, 5-pin, 16 A, 6 h
Operating temperature:
-20 °C to +45 °C
Humidity for operation:
max. 90 % RH
Storage conditions
1)
:
-10 °C to +40 °C
with 20 % to 80 % RH
Dimensions (height x width x depth):
400 x 270 x 255 (mm)
Weight:
5.6 kg
Sound pressure level:
51 dB(A)
No.
Designation
4
relay
5
3 sets heating element 1650 W
6
motor
7
switch
8
thermostat sensor
9
self-resetting thermostat