ceramic heater TDS 30 M / TDS 50 M
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
TDS 30 M
•
Turn the rotary switch (3) of the room thermostat to
position
MIN
.
•
Turn the selection switch (4) to the
position (ventilation
only).
•
Keep the fan running for 3 minutes before switching the
device off.
•
Switch off the device by setting the selector switch (4) to
position
0
.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Transport and storage
chapter.
TDS 50 M
•
Switch off the device by setting the selector switch (4) to
position
0
.
•
The fan keeps running for approx. 3 minutes and then
switches off automatically.
•
Wait until the fan has completed the rundown operation.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Transport and storage
chapter.
Errors and faults
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
•
Check the room temperature. The room thermostat may
have switched off, because the desired room temperature
has been reached.
•
The motor might be defective. Have a defective motor
replaced by a specialist electrical company.
•
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
•
The overheating protection may have been tripped. Have a
specialist electrical company or Trotec check the electrics
and replace the overheating protection.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is switched on, the fan is operating, the heating
is not:
•
Check whether a heating level is selected.
•
Check the room temperature. The room thermostat may
have switched off, because the desired room temperature
has been reached.
•
Check whether the overheating protection has tripped (see
chapter Safety).
•
The heating resistor might have blown. Have a defective
heating resistor replaced by a specialist electrical
company.
•
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
The fan is not running:
•
Check whether the device is switched on.
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
The fan motor might be defective. Have a defective fan
motor replaced by a specialist electrical company.
Содержание TDS 10 M
Страница 1: ...TRT BA TDS30M TDS50M TC2017 29 007 EN TDS 30 M TDS 50 M EN ORIGINAL INSTRUCTIONS CERAMIC HEATER ...
Страница 12: ...12 EN ceramic heater TDS 30 M TDS 50 M Circuit diagram TDS 30 M ...
Страница 13: ...EN 13 ceramic heater TDS 30 M TDS 50 M Circuit diagram TDS 50 M ...
Страница 17: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...