EN
9
convector TCH 21 E / TCH 23 E
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Turn the function selector switch (
7
) to
0
.
•
Turn the rotary switch of the room thermostat (
8
) counter-
clockwise until reaching the
MIN
position.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Transport and storage
chapter.
Errors and faults
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
•
Check the room temperature. The room thermostat may
have switched off, because the desired room temperature
has been reached.
•
Check whether the device is standing upright and on level
ground. The tilt protection may have been tripped owing to
the fact that the device was knocked over. Always put up
the device in an upright position on a suitable, sufficiently
dimensioned surface.
•
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
•
The overheating protection may have been tripped. Have a
specialist electrical company or Trotec check the electrics
and replace the overheating protection.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The air current is reduced:
•
Check the air inlet and outlet. Make sure that air inlet and
outlet are not obstructed. Remove any dirt. Observe the
minimum distance from walls or other objects according to
the technical data.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Warning of electrical voltage
Never immerse the device in water!
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.