8
EN
convector TCH 1500 E
Setting the heating level
The device is provided with 10 heating levels which you can
select using the remote control or the control panel.
ü
The device is switched on.
1. Press the
Heating level
button (14) to increase the heating
level.
ð
The
Heating level
indication (22) on the display is
adapted accordingly.
2. Press the
Heating level
button (14) again to increase the
heating level further. When the highest heating level has
been reached, the device automatically skips back to the
lowest heating level when the "Heating level" button is
pressed again.
Eco mode
The device is provided with an Eco mode in which the room
temperature is slowly increased to 26 °C (e.g. in offices). In the
Eco mode, the temperature and the heating level cannot be
adapted. Proceed as follows to switch on the Eco mode:
1. Press the
Eco
button (12).
ð
The Eco mode is activated.
ð
The
Eco mode active
indication (23) lights up on the
display.
2. Press the
Eco
button (12) again or press the
heating
level
button (14) to exit the Eco mode.
Setting the timer
The timer has the following modes of operation:
•
automatic switch-on upon expiry of a preset number of
hours
•
automatic switch-off upon expiry of a preset number of
hours
The number of hours to be set can be between 1 and 24 and is
adjustable in increments of 1 hour.
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-on
ü
The device is in standby mode.
1. Press the
timer
button (11).
ð
The
timer mode active
indication (24) lights up on the
display.
ð
The display indicates a switch-on time of 0 hours.
2. Select the desired number of hours by use of the
increase
value
(10) or
decrease value
(15) button.
ð
The number of hours flashes on the segment
display (17).
ð
The time until automatic switch-on is saved.
ð
After approx. 1 minute the segment display goes off.
The
timer active
indication (24) is illuminated until the
device switches on automatically.
Automatic switch-off
ü
The device is switched on.
ü
The device runs at the set heating level.
1. Press the
timer
button (11).
2. Select the desired number of hours by use of the
increase
value
(10) or
decrease value
(15) button. If you select
0 hours, the timer will be off.
ð
The number of hours flashes on the segment
display (17).
ð
The time until automatic switch-off is saved.
ð
For approx. 1 minute, the segment display changes
between the display of the switch-off time and that of
the temperature selected.
ð
After approx. 1 minute the segment display goes off.
The
timer active
(24) and
heating function active
(25)
indications are lit until the device switches off
automatically.
Notes regarding automatic switch-off:
•
Manually switching the device off disables the automatic
switch-off function.
•
If you select 0 hours, the timer will be off.
Activating/deactivating the automatic display switch-off
function
The device is provided with an automatic display switch-off
function which switches off the display after approx.
60 seconds. The following indications are not deactivated:
•
Child lock active
indication (20)
•
Standby
indication (21)
•
Timer active
indication (24)
•
Heating function active
indication (25)
In the factory default, the automatic display switch-off function
is activated. Please proceed as follows to deactivate the
automatic display switch-off function:
1. Simultaneously press and hold the
timer
(11) and
heating
level
(14) buttons for approx. 3 seconds.
ð
The display switch-off function is deactivated. All
indications in the display remain stored (if they are
active).
2. Simultaneously press and hold the
timer
(11) and
heating
level
(14) buttons for approx. 3 seconds if you wish to
activate the display switch-off function again.