Technical data

Parameter

Value

Model

TAC 1500

TAC 3000

Article number

1.580.000.105

1.580.000.115

Recommended air volume for dust class H (m³/h)

500

1000

Dust class (as per DIN EN 60335-2-69)

Dust class H (transmittance ≤ 0.005%) for substances with a maximum allowable concentration of 
≤ 0.1 mg/m³, carcinogenic hazardous substances as per GefStoffV § 11 (Ordinance on Hazardous 
Substances), TRGS 905 or 906 (Technical Rules for Hazardous Substances), 
approvable for asbestos abatement as per TRGS 519

Infinite adjustment of air volume

yes

yes

Filter change indication, visual and acoustic

yes

yes

Vario-shift function for the variable configuration of use with 
terminal fan or HEPA filter

yes

yes

Motor power

175 W

450 W

Input voltage

230 V / 50-60 Hz

230 V / 50-60 Hz

Current consumption

1.4 A

2.8 A

Electrical connection

Safety plug (CEE 7/7)

Connecting cable

Rubber conduits (H05RN-F), length 3 m

Air transport hose (blow-out and suction side)

200

250

Sound level (distance 1 m)

61 dBA

65 dBA

Dimensions (L x W x H)

705 mm x 362 mm x 377 mm

833 mm x 460 mm x 519 mm

Weight (full)

22 kg

36 kg

Mobility: portable / wheeled / stackable

yes / yes / yes

yes / yes / yes

Recommendation for filter combinations specific to the application and corresponding 
room size suitability

TAC 1500

TAC 300

suitable for rooms sized up to

1)

Fields of application

Filter combination

m

3

m

3

m

3

m

3

Coarse dust 

2)

 (≤ 3 LW/h

6)

)

G4

220

75

500

170

Fine particulates 

3)

 (≤ 3 LW/h

6)

)

G4 + F7 to F9

110

37

270

90

Suspended matter 

4)

 (≥ 10 LW/h

6)

)

G4 + H13

50

17

100

34

Hygienic areas 

5) 

(≥ 15 LW/h

6)

)

G4 + H13

35

12

70

23

Optional equipment

TAC 1500

TAC 3000

Guiding wheels with pneumatic tyres, traceless

upon request

upon request

Trestle rollers (instead of guiding wheels)

upon request

upon request

Fork pockets for fork lifts

upon request

upon request

Filter elements (accessory consumables)7)

TAC 1500

TAC 3000

G4 Z line filter

Article number
7.160.000.404

Article number
7.160.000.428

F7 pleated filter cartridge

Article number
7.160.000.409

Article number
7.160.000.429

F7 bag filter

Article number
7.160.000.414

Article number
7.160.000.430

H13 HEPA filter approved for dust class H

Article number
7.160.000.424

Article number
7.160.000.431

Available accessories

TAC 1500

TAC 3000

Air transport hose Tronect SP-T,
length 7.6 m

Article number
6.100.001.200

Article number
6.100.001.205

Professional extension cable,
length 20 m, 230 V / 2.5 mm²

Article number
7.333.000.376

Article number
7.333.000.376

Содержание TAC 1500

Страница 1: ...OPERATING MANUAL AIR CLEANER TAC 1500 TAC 3000 EN TRT BA TAC1500_3000TC 004 EN...

Страница 2: ...ges to construction in the interests of constant improve ments to the product as well as changes to the shape and colour are reserved The scope of delivery may vary from product images This docu ment...

Страница 3: ...sing during the above mentioned operations A TAC air cleaner is fundamentally made up of the following com ponents housing adjustable fan for air transport filter boxes for the integration of filter t...

Страница 4: ...und Any unau thorised changes modifications or alterations of the device are forbidden Personnel qualifications People who use this device must be aware of the dangers that occur when working with ele...

Страница 5: ...es must be connected as indicated in the figure below Fig 3 Connection diagram of pressure sensor hoses in the cleanroom arrangement Standard arrangement Here the motor is positioned as the last eleme...

Страница 6: ...in the pre filter box Fig 6 b Bag filter arrangement wiring For proper monitoring of the filter technology the pressure sensor hoses must be connected as indicated in the figure below Fig 7 Connectio...

Страница 7: ...led via a hose from the room into the air inlet of the device The purified air is fed through another hose from the air outlet and back into the room In ventilation mode the air to be cleaned is led v...

Страница 8: ...nel Fig 12 Side view 2 of TAC 3000 without side panel Fig 13 Side view 2 of TAC 1500 without side panel Shutdown 1 Switch off the device 2 Remove the mains plug from the mains socket 3 Clean the devic...

Страница 9: ...e mains plug with wet or damp hands Before any work detach the mains plug Maintenance tasks which require the housing to be opened must only be carried out by a specialist com pany or by TROTEC Filter...

Страница 10: ...n the pre filter box and the fan housing 8 Mount the side panels Make sure that the side panels are grounded Fig 16 Removing the filter When the device warns of a spent pre filter and or HEPA filter s...

Страница 11: ...horized changes of the facto ry supplied device version this declaration loses its legal validity Device version Air Cleaner Series TAC Year of manufacture as of April 2014 Applicable regulations Appl...

Страница 12: ...200 250 Sound level distance 1 m 61 dBA 65 dBA Dimensions L x W x H 705 mm x 362 mm x 377 mm 833 mm x 460 mm x 519 mm Weight full 22 kg 36 kg Mobility portable wheeled stackable yes yes yes yes yes ye...