Speedy 360
BA 8032_2.2_EN (05/2016)
31 / 90
www.troteclaser.com
4.3
Electrical requirements
Laser Power
35
–50 W (CO
2
)
10-50 W (fiber)
AC
55
–80 W (CO
2
)
10-50 W (fiber)
AC
85
–100 W
(CO
2
)
10-50 W
(fiber)
AC
105
–120 W
(CO
2
)
10-50 W
(fiber)
AC
Voltage
230VAC 115VAC
230VAC
115VAC
230VAC
230VAC
Fuse
8AT
16AT
10AT
16AT
12AT
12AT
Power consumption
1200 W
1200 W
1400 W
1400 W
1900 W
1900 W
* AC = air condition
Inadequate or inappropriate power sources can lead to machine damage and are not
covered by any liability.
Verify that the electrical outlet is capable of providing the proper voltage, frequency and
amperage required by the laser machine described in this manual.
Electrical noise, unstable power supply as well as voltage spikes in power supply can
cause interference and possible damage to the electronics of the laser machine.
Use an individual circuit for the laser machine and the PC and an individual circuit for the
exhaust system. Install your computer on the same circuit as the laser machine to
prevent electromagnetic interactions.
Furthermore it is highly recommended that you use a surge suppression plug to protect
your computer equipment.
If electrical power fluctuations, brownouts or power outages are a problem in your area,
an electrical line stabilizer, UPS (Uninterruptible Power Supply) or backup generator are
required. When installing any of these devices, ensure that they meet the electrical
requirements of the laser machine.