![Trotec PRTS 10-1200 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/trotec/prts-10-1200/prts-10-1200_instruction-manual_1172293017.webp)
EN
17
routing machine PRTS 10-1200
Milling with the guide bush
The template must be at least as high as the guide ring (
37
) of
the guide bush (
16
).
ü
If the extraction adapter (
30
) is fitted, it must be dismantled
beforehand.
1. Insert the guide bush (
16
) into the base plate (
5
) from
below, with the guide ring (
37
) pointing downwards.
2. Attach the guide bush (
16
) using the supplied Phillips
screws (
36
).
5
16
36
36
37
3. Insert a milling cutter whose diameter is smaller than the
inner diameter of the guide bush (
16
).
4. Release the locking lever (
4
) and lower the device until the
preset milling depth is reached.
5. Guide the device along the template with the guide
ring (
37
) protruding. Meanwhile, apply slight and even
pressure.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch off the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
If required, allow the device to cool down.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Transport and storage
chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Troubleshooting tasks which require the housing to be opened
must only be carried out by an authorized specialist electrical
company or by Trotec.
Light smoke or odour is emitted during the first use:
•
This is not a fault. These phenomena disappear after a
brief runtime.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage. If you
notice damages, do not try to take the device back into
operation.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
•
Check the on-site fusing.
Info
Wait for at least 10 minutes before switching the
device back on.
The device becomes hot:
•
Make sure not to exert too much pressure on the device
during operation.
•
Keep the venting slots clear to prevent the motor from
overheating.
•
Wait for at least 10 minutes before switching the device
back on.