![Trotec PJSS 12-230V Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/trotec/pjss-12-230v/pjss-12-230v_original-instructions-manual_1172287017.webp)
EN
17
850W pendulum action jigsaw PJSS 12-230V
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Troubleshooting tasks which require the housing to be opened
must only be carried out by an authorized specialist electrical
company or by Trotec.
Light smoke or odour is emitted during the first use:
•
This is not a fault. These phenomena disappear after a
brief runtime.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage. If you
notice damages, do not try to take the device back into
operation.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
•
Check the on-site fusing.
Info
Wait for at least 10 minutes before switching the
device back on.
The saw blade is loose:
•
Make sure that the saw blade is firmly locked in place in
the designated recesses of the quick-release chuck.
•
Make sure that the quick-release chuck is locked.
The saw blade experiences difficulties penetrating the
material to be processed or the sawing performance is
insufficient:
•
Check the set stroke rate; it must be suitable for both the
saw blade and the material.
•
To select a higher stroke rate, turn up the setting wheel for
stroke rate selection.
•
Check whether the pendulum action setting is suitable for
the material to be processed.
•
If the saw blade is worn, replace it with a new one.
•
Check whether the chosen saw blade is suitable for the
material to be processed.
The device becomes hot:
•
Make sure not to exert too much pressure on the device
during sawing.
•
To select a low stroke rate, turn down the setting wheel for
stroke rate selection.
•
Check whether the chosen saw blade is suitable for the
task to be carried out.
•
Keep the venting slots clear to prevent the motor from
overheating.
Info
Wait for at least 10 minutes before switching the
device back on.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.