Trotec PAC-W 2600 SH Скачать руководство пользователя страница 14

14

EN

monobloc air conditioner without external unit PAC-W 2600 SH

WiFi connection

Proceed as follows to establish a WiFi connection:

ü

The device is now in standby mode.

1. Download the Trotec Assistent App and open it on a

smartphone.

2. Select 

Add Device

 by pressing the + sign in the top right

corner.

3. Select 

Large household appliances

 and 

Air conditioning

(Wi-Fi)

 among them.

4. Press the 

fan speed

 button (18) on the control panel of the

device for approx. 3 s.

ð

The 

Wifi

 LED (22) lights up.

5. Press the 

fan speed

 button (18) again on the control panel

of the device for approx. 3 s.

ð

The 

Wifi

 LED (22) flashes approx. 2 times per second.

ð

The device is in 

Quick Connect

 mode.

6. Follow the instructions of the app on the smartphone.

ð

Once the 

Wifi

 LED (22) is permanently illuminated, the

connection is established.

Info

If the WiFi connection is interrupted, the device may
not automatically reconnect to the network. If this is
the case, re-establish the connection with the 

fan

speed

 button (18).

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch off the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Clean the device according to the Maintenance chapter.

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

Observe the operating temperature according to the
chapter Technical annex.

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The device works with reduced or no cooling capacity:

Check whether 

cooling

 mode is selected.

Check the position of the ventilation flaps. They should be
opened to the maximum.

Check the air filter(s) for dirt. If necessary, clean or replace
the air filter(s).

Check whether any windows and/or doors of the room are
open. If so, close them.

Check the temperature setting at the device. Reduce the
set temperature if it is higher than the room temperature.

Condensate is leaking:

Check the device for leaks.

The compressor does not start:

Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10 minutes before
reconnecting it.

Check whether the ambient temperature equals the target
temperature (in 

cooling

 mode). The compressor will not

switch on unless the respective temperature is reached.

The compressor may start up with a delay of 3 minutes, as
it is provided with an internal protection against direct
restart.

The device gets very warm, is loud or is losing
performance:

Check the air inlets and air filters for dirt. Remove external
dirt.

From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.

The device does not respond to the infrared remote control:

Check whether the distance between remote control and
device is too large and reduce it if necessary.

Make sure there are no obstacles, such as furniture or
walls, between the device and the remote control. Ensure
visual contact between device and remote control.

Check the charging status of the batteries and change
them if required.

If the batteries have just been changed, check them for
correct polarity.

Note

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

The device still does not operate correctly after these
checks:

Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.

Содержание PAC-W 2600 SH

Страница 1: ...TRT BA PAC W2600SH TC2020 56 004 EN PAC W 2600 SH EN OPERATING MANUAL MONOBLOC AIR CONDITIONER WITHOUT EXTERNAL UNIT ...

Страница 2: ...f conformity via the following link PAC W 2600 SH https hub trotec com id 44836 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all ...

Страница 3: ...Safety warnings for devices containing flammable refrigerants Only position the device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is no source of ignition e g open flames an active gas appliance or an electric heater Please note that the refrigerant is odourless Only install the device in compliance with the national installation ...

Страница 4: ...ifications and by persons having a certificate of qualification A corresponding repair manual is available from the manufacturer upon request ACHTUNG 1 Vor Inbetriebnahme MIND 12 STUNDEN aufrecht und still stehenlassen Das schützt den Kompressor verlängert die Lebensdauererheblich und verhindert so einen Verlust der Kühlleistung 2 Das Klimagerät muss immer BESONDERS VORSICHTIG auf denBoden gestell...

Страница 5: ...ing of hot surface In heating mode the ventilation flap at the air outlet may become very hot and cause burns Do not touch the ventilation flap during and after heating operation Risk of burns Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way Observe the personnel qualifications Warning The device is not a toy and does not belong in th...

Страница 6: ...rovides the opportunity of air circulation without cooling effect In dehumidification mode moisture is withdrawn from the air In heating mode the room air is warmed up The device operates fully automatically and features a variety of further options The device can for instance be switched on or off automatically with time delay via the timer function The inverter technology of the device allows it...

Страница 7: ...y warranty claims will be voided in this case Storage Before storing the device observe the following Drain the remaining condensate from the device Hold onto the mains plug while pulling the power cable out of the mains socket When the device is not being used observe the following storage conditions Only store the device in a room measuring more than 15 m2 Only position the device in rooms where...

Страница 8: ...s as well as the exhaust air hose connection free Make sure that no curtains or other objects interfere with the air flow Inserting the air filter Note Do not operate the device without an inserted air filter Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Make sure that the air filter is installed be...

Страница 9: ...y using the 20 mm masonry drill bit and the 180 mm core drill bit Warning Before and during assembly ensure that no persons are endangered by the material removed towards the outside The last part of the installation must be carried out with the utmost care and with little pressure so that the exterior plaster is not damaged 4 Use the template to mark the positions of the screws for the suspension...

Страница 10: ... ring This will firmly hold the external cover in position 14 Secure the chains and cut off excess chain links 15 Lift the device onto the wall align the holes where the device is to be mounted with the hooks on the suspension rail and carefully place the device in position At the same time push the drain pipe through the drain hole Prior to initial start up insert batteries in the remote control ...

Страница 11: ...Automatic switch on timer function in increments of 1 hour 1 h to 24 h Automatic switch off timer function in increments of 1 hours 1 h to 24 h 20 Decrease value button Reducing the target temperature 16 C to 30 C for cooling or heating For reducing the number of hours when programming the timer 21 Increase value button Increasing the target temperature 16 C to 30 C for cooling or heating For incr...

Страница 12: ...on the segment display 9 Heating Warning of hot surface In heating mode the ventilation flap at the air outlet may become very hot and cause burns Do not touch the ventilation flap during and after heating operation Risk of burns In heating mode the room will be heated up to the desired target temperature 1 Press the mode button 17 until the heating LED 13 is illuminated ð Heating mode is selected...

Страница 13: ...ch off 3 Wait for 3 seconds to confirm the setting ð The number of hours until automatic switch on will be indicated on the segment display 9 for approx 3 s ð The H LED is illuminated on the control panel ð After the predefined time the device switches itself off Notes regarding automatic switch off If the device is disconnected from the power supply all settings for automatic switch on are delete...

Страница 14: ...ether cooling mode is selected Check the position of the ventilation flaps They should be opened to the maximum Check the air filter s for dirt If necessary clean or replace the air filter s Check whether any windows and or doors of the room are open If so close them Check the temperature setting at the device Reduce the set temperature if it is higher than the room temperature Condensate is leaki...

Страница 15: ...rcurrent protection PC Exhaust temperature protection P2 DC bus voltage undervoltage protection E3 DC fan feedback failure indoor E4 Communication error indoor and outdoor P6 Coil tube overload protection indoor F6 PCB communication error P7 Defrost protection on coil tube indoor P3 AC Input voltage protection E2 Sensor error on indoor coil tube P4 AC overcurrent protection E1 Temperature sensor e...

Страница 16: ... condensation tray and drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Check for d...

Страница 17: ...ec Safety signs and labels on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp and lint free cloth Make sure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol b...

Страница 18: ...ains If you do not intend to use the device for a considerable time Store the device according to the Transport and storage chapter Technical annex Technical data Model PAC W 2600 SH Cooling capacity 2 6 kW Heating capacity 2 kW Dehumidification performance 1 2 l h Operating temperature 7 C to 35 C Temperature setting range 16 C to 30 C Max air volume flow 500 m3 h Pressure suction side 1 3 MPa Pr...

Страница 19: ...EN 19 monobloc air conditioner without external unit PAC W 2600 SH Circuit diagram ...

Страница 20: ... conditioner without external unit PAC W 2600 SH Overview and list of spare parts Note The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual ...

Страница 21: ...trol box 35 Water level switch 59 Electronic expansion valve nozzles 1 12 Variable frequency drive plate 36 Water release switch assembly 60 Four way valve connection 2 13 Main control panel 37 Underwater pans 61 Four way valve connection 1 14 Isolation column 38 Base 62 Condenser assembly 15 Line pressing board 39 Afer cover plate 63 Compressor discharge pipe 16 Left support plate 40 Back panel 6...

Страница 22: ...her forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment Have the refrigerant propane disposed of appropriately and according to the national regulations by a company with the relevant certification European Waste Catalogue 160504 In the European Union b...

Страница 23: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: