8
EN
radiant heater IR 2550 S / IR 2570 S
The following is required for installation:
•
a pencil for marking the drill holes
•
a suitable drill
•
wall plugs appropriate for the structure of the wall
•
a screwdriver
•
a spirit level
1. Mark the drill holes on the wall.
2. Drill the holes into the wall at the marked positions.
3. Insert suitable wall plugs into the drill holes.
4. Screw the mounting brackets to the wall.
5. Check the mounting brackets for tight fit.
6. Tilt the device to the desired angle. The device can be
tilted upwards and downwards by 90°.
90°
Start-up
Info
Odours might arise upon initial start-up or after a
longer period of non-use.
•
Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
•
Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
•
Make sure that extension cables are completely unrolled.
•
Make sure that there are no curtains or similar objects in
the immediate vicinity.
Prior to initial start-up, insert batteries in the remote control.
Connecting the power cable
•
Insert the mains plug into a properly secured mains power
socket.
•
Make sure that the power cable is guided along the back
of the device. Never guide the power cable along the front
of the device!
Info
As soon as power is available, the operating light (7) is
permanently illuminated, even if the device has not
been switched on.