EN
8
oil heater IDX 30 D
Unclean combustion:
•
The air filters might be dirty. Check the pressure at the
pump and adjust it if necessary, see chapter Adjusting the
air pressure for the pump.
•
The fuel might be of poor quality. Completely drain the
fuel, see chapter Draining the tank. Refill new fuel, see
chapter Filling the tank.
•
The pump pressure might be incorrect. Check the pressure
at the pump and adjust it if necessary, see chapter
Adjusting the air pressure for the pump.
Smoke and/or sparks are emitted during first use:
•
This is not a fault. These phenomena disappear after a
brief runtime.
Noise emission during ignition or cooling:
•
This is not a fault. The metal parts of the device expand
when heated and generate noise.
Sparks and/or flame may be issued from the device during
ignition:
•
This is not a fault. Air might have accumulated in the lines.
Keep a safety distance to the device!
The flame in the combustion chamber does not ignite:
•
Check the filling level of the tank. Refill fuel if the tank is
empty (see chapter Maintenance).
•
Check the fuel for contaminations, e.g. dirt or water. If
required, drain the fuel completely and fill in new fuel (see
chapter Maintenance).
•
Safety shutdown: if the flame dies during operation, the
electronics and the oil pump will be switched off.
Investigate the cause on the basis of the following criteria:
–
For qualified personnel only!
Check the ignition: The distance between the two
ignition electrodes should be 4 to 5 mm.
The flame goes out during combustion:
•
Make sure the air supply is unobstructed. If required, clean
the air intake opening.
•
Check the filling level of the tank. Refill with fuel if the tank
is empty (see chapter Operation).
•
Moisture in tank or fuel. Please contact the customer
service.
•
Check the fuel for contaminations and replace it if
required.
•
Power failure: In the event of a power failure the ignition is
extinguished, the device switches off immediately. After a
power failure the device will not restart automatically, it
has to be started via the on/off switch.
The device emits smoke or dust:
•
Check the mains voltage.
•
Check the fuel for contaminations and replace it if
required.
•
Check the tank for contaminations and drain it if required
(see chapter Maintenance). Refill with clean fuel.
The flame emerges from the air outlet:
•
Check the mains voltage.
•
Check the fuel for contaminations and replace it if
required.
•
Check the tank for contaminations and drain it if required
(see chapter Maintenance). Refill with clean fuel.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.