background image

15

EN

oil heater IDX 30 D

Adjusting the air pressure for the pump

Ideally, the air pressure should range between 0.32 bar and
0.36 bar. During operation, the air pressure can be read from
the pressure gauge (5).

Info

If the air pressure exceeds 0.36 bar, a flame emerges
from the air outlet of the device. The device then stops
running.
If the pressure is lower than 0.32 bar, the device
continues to operate, but with a reduced performance.

1. Adjust the air pressure during operation by means of a

slotted screwdriver. For lowering turn the screw counter-
clockwise; for increasing carefully turn it clockwise.

0,6

0,8

1

0

0,2

0,4

Technical annex

Technical data

Parameter

Value

Article number

1.430.000.066

Method of heating

direct

Amount of air

735 m³/h

Fan

Axial fan

Mains connection

1/N/PE~220–240 V / 50 Hz

Nominal heat output

30 kW (25,800 kcal)

Temperature increase ΔT

90 °C (1.5 m distance)

Input voltage

230 V / 50 Hz

Current consumption

0.8 A

Max. fuel consumption

2.9 l/h

Sound level (distance 1 m)

65 dB(A)

Weight

20 kg

Dimensions 
(length x width x height)

388 x 942 x 460 (mm)

Minimum distance to walls or
other objects

3 m

Fuels

The following fuels are approved for the device:

EL fuel oil

Kerosene

Diesel

Содержание IDX 30 D

Страница 1: ...TRT BA IDX30D TC 002 EN IDX 30 D EN ORIGINAL INSTRUCTIONS OIL HEATER ...

Страница 2: ...ia the following link IDX 30 D https hub trotec com id 40041 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instru...

Страница 3: ...the device observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter Do not use the device in immediate proximity to curtains Make sure that the air inlet and outlet are not obstructed Make sure that the suction side is kept free of dirt and loose objects Do not place the device on combustible ground Only tran...

Страница 4: ...here is an imminent fire hazard Behaviour in the event of an emergency 1 In case of an emergency immediately extinguish the pilot flame by actuating the on off switch position 0 2 In an emergency disconnect the device from the mains feed in Switch the device off and disconnect it from the mains 3 Remove persons from the danger area 4 Do not reconnect a defective device to the mains Overheating pro...

Страница 5: ...follows Switch off the device Hold onto the mains plug while pulling the power cable out of the mains socket Do not use the power cable to drag the device Allow the device to cool down sufficiently While transporting the device observe the following Slightly lift the device by the transport handle 2 until the rear support no longer touches the ground Wheel the device to the desired position Storag...

Страница 6: ...e axle must be attached to the frame To do so please proceed as follows 1 Slide the axle through the openings at the frame 2 Attach both wheels to the axle 3 Attach the locking rings to the axle 4 Fasten the wheel caps to the wheels Info If necessary the frame can be disassembled again e g for storage To remove the wheels from the axle you can carefully loosen the wheel caps and locking rings by m...

Страница 7: ...ls or large objects near the device The inlet and outlet openings must not be covered There must be a sufficient number of fire extinguishers available 25 30 35 40 45 5 10 15 20 3 m 3 m 3 m 3 m 3 m Start up Check the scope of delivery of your device for completeness If an accessory part is missing please contact the Trotec customer service or the specialist dealer where you purchased the device Ch...

Страница 8: ...specialist companies or by Trotec Warning Risk of injury due to improper repair Never try to make any modifications or repairs on the device Unauthorised modifications can lead to serious injuries or death Have a certified specialist workshop perform the repair work The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device...

Страница 9: ...the cause on the basis of the following criteria For qualified personnel only Check the ignition The distance between the two ignition electrodes should be 4 to 5 mm The flame goes out during combustion Make sure the air supply is unobstructed If required clean the air intake opening Check the filling level of the tank Refill with fuel if the tank is empty see chapter Operation Moisture in tank or...

Страница 10: ...y after cleaning Filling the tank The fuel tank cap and the filling level indication are located to the left of the control panel ü Before attempting to fill the tank wait until the device has cooled down completely ü Only use fuel suitable for the device see technical data 1 Position the device on firm level and incombustible ground 2 Unscrew the fuel tank cap 9 IDX 30 D THERMOSTAT CONTROL ROOM T...

Страница 11: ...r filters should be checked cleaned and possibly replaced approx every 500 operating hours The fan ought to be checked for dirt at least once per heating season This activity can be carried out along with the inspection of the air filters Overview of air filters The filter housing consists of the following parts filter seal 30 prefilter 31 foam filter 32 filter housing 33 30 31 32 33 Opening the h...

Страница 12: ...T CONTROL ROOM TEMP CLOSE OPEN IDX 30 D Cleaning the fan blades 1 Carefully clean the fan blades with a soft damp and lint free cloth Ensure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth THERMOSTAT CONTROL ROOM TEMP 0 6 0 8 1 0 0 2 0 4 ...

Страница 13: ...leaning or replacement 1 Remove the two filters from the filter housing 33 30 31 32 33 2 Check both filters for dirt or damage Replace the prefilter 31 if needed If required clean the foam filter 32 using a slightly damp soft lint free cloth If the foam filter is heavily contaminated clean it with warm water mixed with a neutral cleaning agent 3 Allow the foam filter to dry completely Do not put a...

Страница 14: ...lter housing 33 Ensure the proper seating of the seal 30 30 31 32 33 Assembling the filter housing 1 Attach the filter housing with filters and sealing 2 Tighten the hexagonal bolts at the filter housing 3 Fasten the pressure gauge in place 0 6 0 8 1 0 0 2 0 4 ...

Страница 15: ... the housing on the device THERMOSTAT CONTROL ROOM TEMP CLOSE OPEN IDX 30 D 2 Tighten the 8 screws at the upper part of the housing IDX 30 D THERMOSTAT CONTROL ROOM TEMP 0 6 0 8 1 0 0 2 0 4 CLOSE OPEN 3 Attach the protective grid IDX 30 D 4 Tighten the 4 screws at the protective grid IDX 30 D ...

Страница 16: ...ted screwdriver For lowering turn the screw counter clockwise for increasing carefully turn it clockwise 0 6 0 8 1 0 0 2 0 4 Technical annex Technical data Parameter Value Article number 1 430 000 066 Method of heating direct Amount of air 735 m h Fan Axial fan Mains connection 1 N PE 220 240 V 50 Hz Nominal heat output 30 kW 25 800 kcal Temperature increase ΔT 90 C 1 5 m distance Input voltage 23...

Страница 17: ...EN 16 oil heater IDX 30 D Wiring diagram ...

Страница 18: ...17 EN oil heater IDX 30 D Spare parts drawing and list Info The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual ...

Страница 19: ... Grounding Plate 35 Fuel Line Hose 5 4 Rotor Kit 15 Fixation Part 36 Ignitor Wire 5 5 Blade 16 Fuel Tank 37 Photocell 5 6 End Pump Cover 17 Supporting Bracket 38 Photocell Bracket 5 7 Output Filter small 18 Power Cord 39 Fuel Gauge Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household w...

Страница 20: ...version 2006 42 EC Product model Product IDX 30 D Product type oil heater Year of manufacture as of 2018 Relevant EU directives 2014 30 EU 29 March 2014 Applied harmonised standards EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 2015 EN 60335 1 2012 EN 60335 1 2012 A11 2014 EN 60335 2 30 2009 A11 2012 AC 2014 EN 60335 2 102 2016 EN 61000 3 2 2014 EN 61000 3 3 2013 Applied national standards and techni...

Страница 21: ......

Страница 22: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: