oil heater IDS 30 F
Flue duct
The following schematic representation should be considered
when planning a flue duct:
13
26
27
28
29
No.
Designation
13
Flue pipe connection
26
C
leaning opening with explosion protection flap
27
Outer wall
28
F
lue – inside min. 20 x 20 cm
29
Wall duct with elbow min. 5°
Dimensions:
•
A: min. 1 m
•
B: min. 1 m
•
C: as short as possible
•
D: ≥ Ø 120 mm / 150 mm
Wall duct
The following schematic representation should be considered
when planning a wall duct:
13
27
30
29
No.
Designation
13
Flue pipe connection
27
Outer wall
29
Wall duct with elbow min. 5°
30
Draught booster H-shaped
Dimensions:
•
A: min. 1 m
•
B: min. 1 m
•
C: as short as possible
•
D: ≥ Ø 120 mm / 150 mm
•
E: min. 1 m