background image

TRT-BA-IDE20D-30D-50D-60D-100D-TC-001-EN

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D /

IDE 100 D

EN

OPERATING MANUAL

OIL HEATER

Содержание IDE 100 D

Страница 1: ...TRT BA IDE20D 30D 50D 60D 100D TC 001 EN IDE 20 D IDE 30 D IDE 50 D IDE 60 D IDE 100 D EN OPERATING MANUAL OIL HEATER ...

Страница 2: ...rd with an average risk level which if not avoided can result in serious injury or death Caution This signal word indicates a hazard with a low risk level which if not avoided can result in minor or moderate injury Notice This signal word indicates important information e g material damage but does not indicate hazards Info Information marked with this symbol helps you to carry out your tasks quic...

Страница 3: ...th wet or damp hands Do not expose the device to directly squirting water Never insert any objects or limbs into the device Do not cover or transport the device during operation Do not sit on the device This appliance is not a toy Keep away from children and animals Do not leave the device unattended during operation Check accessories and connection parts for possible damage prior to every use of ...

Страница 4: ...orking with the device Residual risks Warning of electrical voltage Work on the electrical components must only be carried out by an authorised specialist company Warning of electrical voltage Before any work on the device remove the mains plug from the mains socket Hold onto the mains plug while pulling the power cable out of the mains socket Warning of flammable substances Handling fuels entails...

Страница 5: ...e the overheating protection replaced Information about the device Device description The directly fired oil heater IDE 100 D serves the purpose of heating the room air so as to quickly heat large rooms The oil heater runs on EL fuel oil kerosene or diesel it must not be used with petrol heavy fuel oil etc It is an oil heater with direct combustion to be installed in roofed outdoor areas or in roo...

Страница 6: ...6 7 9 11 8 10 IDE 50 D IDE 60 D 1 2 3 4 5 6 7 8 9 10 11 IDE 100 D 1 2 3 4 7 8 9 10 11 5 12 No Designation 1 Combustion chamber housing 2 Transport handle 3 Air inlet with protective grid 4 Fan and motor 5 Fuel tank cap 6 Tank 7 Tank filling level indication 8 Frame 9 Control panel 10 Wheel 11 Air outlet for hot air 12 Fuel pump IDE 100 D only ...

Страница 7: ...from dust and direct sunlight with a cover to protect it from invasive dust if necessary Assembly and installation Scope of delivery 1 x Oil heater 1 x Carry handle IDE 20 D only 1 x Frame components IDE 30 D IDE 50 D IDE 60 D IDE 100 D only 2 x Wheel IDE 30 D IDE 50 D IDE 60 D IDE 100 D only 1 x Installation material 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out...

Страница 8: ...ls in the same room with the device The minimum distance between walls or other objects and the air outlet opening of the device must be at least 3 m see figure The minimum distance between walls or other objects and the air inlet opening of the device must be at least 2 m see figure There must be no walls or large objects near the device The inlet and outlet openings must not be covered There mus...

Страница 9: ...itch 13 is illuminated 2 Set the rotary control 12 to the desired room temperature This value should be higher than the current room temperature 3 Ensure a successful ignition Switching the device off Warning of electrical voltage Do not touch the mains plug with wet or damp hands Notice Damage to the device due to overheating Never switch off the device by pulling the mains plug This may lead to ...

Страница 10: ... electronics and the oil pump will be switched off investigate the cause on the basis of the following criteria For qualified personnel only Check the ignition The distance between the two ignition electrodes should be 4 to 5 mm The flame goes out during combustion Make sure the air supply is unobstructed If required clean the air intake opening Check the filling level of the tank Refill with fuel...

Страница 11: ...side of the control panel The images in the description below show the IDE 100 D by way of example ü Before attempting to fill the tank wait until the device has cooled down completely ü Only use fuel suitable for the device see technical data 1 Position the device on firm level and incombustible ground 2 Unscrew the fuel tank cap 5 THERMOSTAT CONTROL CLOSE OPEN 5 7 3 Fill the tank In doing so obs...

Страница 12: ...o 80 RH Temperature increase ΔT 140 C 210 C 180 C 150 C 350 C Max fuel consumption 1 2 l h 2 4 l h 4 l h 4 8 l h 9 5 l h Tank capacity 12 l 19 l 38 l 56 l 69 l Input voltage 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 220 240 V 50 Hz Current consumption 0 71 A 1 25 A 1 25 A 1 5 A 2 7 A Overheating protection yes yes yes yes yes Connection for external thermostat 45 C 45 C 45 C 45 C 45 C Sound ...

Страница 13: ...t in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and hu...

Страница 14: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: