EN
9
condenser dryer DH 25 S / DH 65 S
Operation
Control panel
•
Avoid open doors and windows.
•
After being switched on, the device operates fully
automatically.
•
The fan runs permanently until the set nominal value is
reached or the device switched off.
•
After a runtime of approximately 35 minutes the device will
switch over to the defrost mode for a duration of about
3 minutes, if required.
8
9
10
11 12
13
14
15
16
17
No. Designation
Meaning
8
POWER
LED
Illuminated during standby and
ongoing operation
9
ALARM
LED
Illuminated in the event of an error
message
10 Segment display
Indication of the desired room humidity
level
11
WORKING
LED
Illuminated when the compressor is
switched on
12
FULL
LED
Illuminated when the condensation
tray is full
13
PUMP
button
Draining of residual water from the
condensation tray
14
HOUR
button
Activation or deactivation of the
operating hours display.
The operating hours are indicated on
the segment display (10).
15
Increase value
button
For increasing the desired relative
humidity level (30 % to 80 %)
16
Decrease value
button
For reducing the desired relative
humidity level (30 % to 80 %)
17
POWER
button
Switching the device on and off
Warning of electrical voltage
Risk of electric shock!
The device does not have the appropriate protection
class for use in wet rooms.
There is a risk of electric shock!
Never use the device in wet rooms (e.g. in bathrooms
and laundry rooms) and never immerse the device in
water!
Switching the device on
Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.
Press the
POWER
button (17). The device starts to dehumidify.
Note
Only use the device in an upright position, otherwise
the compressor could be damaged.
Note
If you switch the device off and back on immediately
afterwards, it will take approx. 4 minutes for the device
to start up again.
Setting the desired room humidity
You can adjust the preset room humidity level at any time
during operation.
1. Press the
Increase value
button (15) or
Decrease
value
button (16), in order to set the desired value (in
increments of 1 % ranging between 30 % and 80 %).
ð
The segment display flashes while you are making the
setting.
2. The segment display will again be illuminated steadily
approx. 4 s after the last input.
ð
The desired room humidity level is set.
Setting continuous operation
The device dehumidifies the air constantly and regardless of the
relative room humidity.
1. Press the
Decrease value
button (16) until the segment
display (10) shows
Cont
.
Содержание DH 25 S
Страница 1: ...TRT BA DH25S DH65S TC220103TTRT03 004 EN DH 25 S DH 65 S EN ORIGINAL INSTRUCTIONS CONDENSER DRYER...
Страница 16: ...16 EN condenser dryer DH 25 S DH 65 S Wiring diagram DH 25 S...
Страница 17: ...EN 17 condenser dryer DH 25 S DH 65 S Wiring diagram DH 65 S...
Страница 25: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...