background image

EN

5

dehumidifier DH 15 / DH 30 / DH 60

Device depiction

DH 15

1

1

2

3

6

4

5, 8

3

DH 30 / DH 60

1

2

6

7

3

4

5, 8

No.

Designation

1

Air outlet

2

Housing

3

Air inlet

4

Hose connector for condensation drain hose 
(inside the device)

5

Control dial hygrostat 
(tamper-proof installation inside the device)

6

Wall holder

7

Suspension

8

MODE

 switch

Transport and storage

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Transport

Always utilize the help of another person to transport the
DH 15 / DH 30. Always utilize the help of two other persons to
transport the DH 60. Do not try to transport the device without
the help of another person. To lift the device, use a forklift or an
elevating truck as appropriate.

Before

 transporting the device, observe the following:

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Do not use the power cable to drag the device.

Drain the remaining condensate from the device.

After

 transporting the device, observe the following:

Set up the device in an upright position after transport.

After having transported the device in horizontal position,
leave the device to rest for 12 to 24 hours, so the
refrigerant can accumulate within the compressor. Wait
12 to 24 hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. Any warranty claims will be voided
in this case.

Содержание DH 15

Страница 1: ...TRT BA DH15 DH30 DH60 TC2019 22 005 EN DH 15 DH 30 DH 60 EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Страница 2: ...nload the current version of the instructions and the EU declaration of conformity via the following link DH 15 https hub trotec com id 42978 DH 30 https hub trotec com id 42979 DH 60 https hub trotec...

Страница 3: ...and operating conditions as given in the Technical data chapter Make sure that the air inlet and outlet are not obstructed Make sure that the suction side is kept free of dirt and loose objects Do no...

Страница 4: ...iple of condensation to automatically dehumidify rooms The fan sucks damp room air through the air inlet the evaporator and the condenser located behind it The air is cooled at the cold evaporator unt...

Страница 5: ...sport the DH 60 Do not try to transport the device without the help of another person To lift the device use a forklift or an elevating truck as appropriate Before transporting the device observe the...

Страница 6: ...ssembly Always utilize the help of another person to assemble the DH 15 DH 30 Always utilize the help of two other persons to assemble the DH 60 Do not try to assemble the device without the help of a...

Страница 7: ...ew the support rail and the device to the wall 6 Set the control dial 5 to the desired humidity level 5 7 Check whether the condensation drain hose is positioned correctly The condensation drain hose...

Страница 8: ...sert suitable wall plugs into the drill holes 4 Screw the support rail to the wall 5 Suspend the device from the wall holder by means of the mounting brackets Utilize the help of one or two other pers...

Страница 9: ...e device operates fully automatically To ensure that the built in sensor can correctly detect the humidity the fan continues to operate until the device is switched off Avoid open doors and windows Op...

Страница 10: ...he condensation drain hose near a water drain For larger distances a longer hose of the same type can also be used 3 Regularly check the condensation drain hose for obstructions or kinks External cond...

Страница 11: ...ected humidity level at the hygrostat s control dial The humidity in the room must be above the selected range Reduce the preselected desired humidity level Have the electrics checked by a specialist...

Страница 12: ...d or condenser dryer X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects...

Страница 13: ...re that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to damp...

Страница 14: ...407C R 407C GWP factor 1 774 1 774 1 774 CO2 equivalent 0 603 t 0 887 t 1 419 t Amount of refrigerant 340 g 500 g 800 g Air volume freely blowing 225 m h 700 m h 1 280 m h Sound pressure level 3 m 49...

Страница 15: ...1 2 DH 30 0 10 20 30 40 50 60 2 15 1 90 1 70 1 50 1 35 1 20 0 80 0 75 0 70 0 65 0 60 0 55 40 30 50 60 70 80 35 30 25 20 15 10 C l 24 h 1 2 DH 60 0 20 40 60 80 100 120 4 1 3 5 3 1 2 6 2 3 1 9 1 3 1 2...

Страница 16: ...16 EN dehumidifier DH 15 DH 30 DH 60 Wiring diagram DH 15 Wiring diagram DH 30 DH 60...

Страница 17: ...rd 3 8 G 1 5 Wall Support 1 22 Remote humidistat socket 1 6 Electrical control cover 1 23 Nut 3 8 G 1 7 Compressor 1 24 Heat exchanger Kit 1 8 Cable gland 1 25 Placa Espuma 255x45x25 2 9 Electronic Co...

Страница 18: ...fier DH 15 DH 30 DH 60 Exploded assembly drawing DH 30 Info The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions 43 44 4...

Страница 19: ...lve coil 1 11 Wall bracket 1 35 Defrost valve 1 12 Compressor 1 36 Cable tie mount 8 13 Condensing coil 1 37 Absorver feet 2 14 Fan 1 38 Insulation foam 1 15 Low pressure switch 1 39 Acoustic insulati...

Страница 20: ...fier DH 15 DH 30 DH 60 Exploded assembly drawing DH 60 Info The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions 44 45 4...

Страница 21: ...cket 1 36 Cable tie mount 12 12 Compressor 1 37 Absorver feet 2 13 Condensator coil 1 38 Insulation foam 1 14 Fan 1 39 Acoustic insulation foam 1 15 Low pressure switch 1 40 Cable Gland 1 16 High pres...

Страница 22: ...ormity The text below sets out the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 42978 Declaration of conformity in accordance...

Страница 23: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: