Trotec AIRGOCLEAN 350E E Скачать руководство пользователя страница 6

6

EN

air cleaner AirgoClean® 350 E

Assembly and start-up

Scope of delivery

• 1 x Device
• 2 x HEPA carbon filter
• 2 x Prefilter
• 1 x Remote control
• 1 x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power

cable is not damaged and that you do not damage it during
unwinding.

Start-up

The HEPA carbon filters are pre-installed.

Note

Remove the plastic cover from the HEPA carbon filters.
To do so, please proceed as described in the chapter
Changing the HEPA carbon filter.

When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical annex.

A

B

C

C

D

• Before restarting the device, check the condition of the

power cable. If there are doubts as to the sound condition,
contact the customer service.

• Only put up the device in an upright, stable position on firm

ground.

• Do not create tripping hazards when laying the power

cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.

• Make sure that extension cables are completely unrolled.
• Position the device near the source of air contamination.
• When positioning the device, keep a sufficient distance to

heat sources.

• Make sure that no curtains or other objects interfere with

the air flow.

• Make sure that the air inlet and outlet are not obstructed.

Connecting the power cable

• Plug in the mains plug of the power cable at the back of

the device.

• Insert the mains plug into a properly fused mains socket.

Содержание AIRGOCLEAN 350E E

Страница 1: ...TRT BA AIRGOCLEAN 350E TC2021 21 001 EN AIRGOCLEAN 350 E EN OPERATING MANUAL AIR CLEANER...

Страница 2: ...he manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock...

Страница 3: ...cated in the immediate surroundings of air inlet and air outlet Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Do not...

Страница 4: ...ight and medium contaminations and odours in order to improve the air quality It is equipped with a powerful fan sucking in the air The air flows through the filter and is cleaned Afterwards the fan r...

Страница 5: ...make the device easier to transport it is fitted with wheels Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power cable out of t...

Страница 6: ...chapter Technical annex A B C C D Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Only put up the device...

Страница 7: ...eed button For setting the fan speed 21 Auto button Switching the automatic mode on or off 22 PM2 5 Timer indication Indication of the particulate matter pollution in g m3 or the number of hours of th...

Страница 8: ...ated in blue good air quality 51 100 Illuminated in red medium air quality 100 Please proceed as follows to switch off the automatic mode 1 Press the Auto button 21 The Auto LED 16 goes out The symbol...

Страница 9: ...peed air quality LEDs 25 are illuminated according to the selected fan stage 3 Press the ionizer button 29 again to deactivate the ionization function The Ionizer LED 10 goes out Setting the timer The...

Страница 10: ...eplace the HEPA carbon filters The prefilter is soiled and has to be cleaned Clean the prefilter see chapter Operation and maintenance The air outlets are obstructed Make sure that the air outlets are...

Страница 11: ...tachment screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign...

Страница 12: ...ir filters 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust clean the inside of the device with a vacuum cleaner 5 Re...

Страница 13: ...ut of the device 35 36 3 Dispose of the HEPA carbon filter according to the national regulations 4 Take the new HEPA carbon filter out of the plastic cover 5 Insert the new HEPA carbon filter 35 into...

Страница 14: ...the prefilter 4 from the device by pressing Push 4 2 Remove the prefilter 37 from the air inlet 4 4 37 3 Clean the filter using a slightly damp soft lint free cloth If the filter is heavily contaminat...

Страница 15: ...for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return opt...

Страница 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: