Trotec AIRGOCLEAN 350E E Скачать руководство пользователя страница 3

EN

3

air cleaner AirgoClean® 350 E

• Check accessories and connection parts for possible

damage prior to every use of the device. Do not use any
defective devices or device parts.

• Ensure that all electric cables outside of the device are

protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

• The mains connection must correspond to the

specifications in the Technical annex.

• Insert the mains plug into a properly secured mains

socket.

• Observe the technical data when selecting extensions to

the power cable. Completely unroll the extension cable.
Avoid electrical overload.

• Before carrying out maintenance, care or repair work on

the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

• Switch the device off and disconnect the power cable from

the mains socket when the device is not in use.

• Do not under any circumstances use the device if you

detect damages on the mains plug or power cable. 
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

• When positioning the device, observe the minimum

distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.

• Make sure that the air inlet and outlet are not obstructed.
• Make sure that there are no loose items or dirt located in

the immediate surroundings of air inlet and air outlet.

• Do not remove any safety signs, stickers or labels from the

device. Keep all safety signs, stickers and labels in legible
condition.

• Do not expose the device to heat or direct sunlight.
• Make sure that the suction side is kept free of dirt and

loose objects.

• Dispose of replaced filters properly, especially after

filtering substances hazardous to health.

• Never use the device as storage place or footstep.
• Do not insert rechargeable batteries into the remote

control.

• Never select automatic mode if the device is used for virus

filtration.

Intended use

Use the device for cleaning the air as well as for odour
elimination (ionization) in interior spaces only whilst adhering to
the technical data and safety instructions.

Foreseeable misuse

• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device outdoors.
• Do not use the device in bathrooms and rooms with a high

humidity level.

• Do not use the device in rooms where large amounts of

dust are produced, e.g. in production halls, workshops or
on construction sites.

• Moreover, the integrated filter system is not suited for

removing dusts that are potentially harmful to health (e.g.
pollutants) from the air.

• Any use other than the intended use is regarded as a

reasonably foreseeable misuse.

• Any unauthorised modifications, alterations or structural

changes to the device are forbidden.

Personnel qualifications

People who use this device must:

• be aware of the dangers that occur when working with

electrically driven air cleaners.

• have read and understood the operating manual, especially

the Safety chapter.

Содержание AIRGOCLEAN 350E E

Страница 1: ...TRT BA AIRGOCLEAN 350E TC2021 21 001 EN AIRGOCLEAN 350 E EN OPERATING MANUAL AIR CLEANER...

Страница 2: ...he manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock...

Страница 3: ...cated in the immediate surroundings of air inlet and air outlet Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Do not...

Страница 4: ...ight and medium contaminations and odours in order to improve the air quality It is equipped with a powerful fan sucking in the air The air flows through the filter and is cleaned Afterwards the fan r...

Страница 5: ...make the device easier to transport it is fitted with wheels Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power cable out of t...

Страница 6: ...chapter Technical annex A B C C D Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Only put up the device...

Страница 7: ...eed button For setting the fan speed 21 Auto button Switching the automatic mode on or off 22 PM2 5 Timer indication Indication of the particulate matter pollution in g m3 or the number of hours of th...

Страница 8: ...ated in blue good air quality 51 100 Illuminated in red medium air quality 100 Please proceed as follows to switch off the automatic mode 1 Press the Auto button 21 The Auto LED 16 goes out The symbol...

Страница 9: ...peed air quality LEDs 25 are illuminated according to the selected fan stage 3 Press the ionizer button 29 again to deactivate the ionization function The Ionizer LED 10 goes out Setting the timer The...

Страница 10: ...eplace the HEPA carbon filters The prefilter is soiled and has to be cleaned Clean the prefilter see chapter Operation and maintenance The air outlets are obstructed Make sure that the air outlets are...

Страница 11: ...tachment screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign...

Страница 12: ...ir filters 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust clean the inside of the device with a vacuum cleaner 5 Re...

Страница 13: ...ut of the device 35 36 3 Dispose of the HEPA carbon filter according to the national regulations 4 Take the new HEPA carbon filter out of the plastic cover 5 Insert the new HEPA carbon filter 35 into...

Страница 14: ...the prefilter 4 from the device by pressing Push 4 2 Remove the prefilter 37 from the air inlet 4 4 37 3 Clean the filter using a slightly damp soft lint free cloth If the filter is heavily contaminat...

Страница 15: ...for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return opt...

Страница 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: