
8
EN
air cleaner AirgoClean® 170 E
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage.
•
Check the on-site fusing.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
•
Check the device cover (
5
) for proper fit.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
The device gets very warm, is loud or is losing
performance:
•
Check the air inlets and air filters for dirt. Remove external
dirt.
The device works with reduced capacity:
•
The air outlet is obstructed. Make sure that the air outlet is
not blocked. Remove any loose objects from the air outlet.
•
The HEPA carbon filter's plastic cover was not removed
before installation. Take the HEPA carbon filter out of the
plastic cover.
The device works with no capacity or the air quality does
not improve:
•
Check whether any windows and/or doors of the room are
open. If so, close them.
•
The HEPA carbon filter is not installed. Install the HEPA
carbon filter.
•
Check the minimum distance to walls or other objects.
Position the device a little more in the room's centre if
required.
The
air quality
LED is illuminated in red for a longer period
of time:
•
Check the c air quality in the room. The air in the room
may be heavily contaminated. Wait for a few minutes to
see whether the colour of the
air quality
LED changes.
•
The air quality sensor is clogged or soiled. Windows and
doors should be closed, otherwise dust and other
contamination is able to enter the room. Clean the air
quality sensor as described in the Maintenance chapter.
The device gives off an unpleasant odour:
•
Check the HEPA carbon filter for dirt. If necessary, clean or
replace the HEPA carbon filter.
•
Smoke, e.g. dense tobacco smoke, odours and
contaminations may be in the air. Ventilate the room.
The
filter change
LED (
13
) flashes:
•
Change the filter as described in the Maintenance chapter.
The segment display (
7
) indicates L3, H8, H3 or ---:
•
Please contact the customer service. If necessary, bring
the device to an authorised specialist electrical company or
to Trotec for repair.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.