EN
7
air cleaner AirgoClean® 150 E
The
speed
LED (
20
) indicates the fan speed in automatic mode.
Air quality
LED
PM2.5 value
Speed
LED
Illuminated in green
(good air quality)
0-70
Stage 1
Illuminated in
orange (medium air
quality)
71-120
Level 2 to 3
Illuminated in red
(poor air quality)
>120
Stage 4
The timer can be optionally activated in automatic mode.
Note
If the light sensor (
8
) detects dark surroundings in
automatic mode, the device automatically switches to
night mode
.
Info
Automatic mode and virus filtration
Do not use the automatic mode if the device is used for
virus filtration!
The integrated sensors only respond to air pollution
caused by fine particulates, pollen or possibly VOC
(organic chemical compounds). The device cannot
determine the virus load inside the room. It is possible
that the automatic mode indicates a "good air quality"
even though the virus load in the room is very high.
Therefore, when using the device for virus filtration, we
recommend that you always select a fixed performance
level adapted to the room size or the required
circulation rate.
Night mode
In
night mode
, the device generates an air current that is
adapted to your sleep habits.
Proceed as follows to switch on night mode:
ü
Measuring the air quality is not activated and the
air
quality
LED (
9
) is not illuminated.
1. Press the
sleep
button (
15
) to activate the night mode.
ð
The
sleep
LED (
14
) is only dimly lit.
ð
The device operates at fan stage 1.
Ventilation
In this mode you can select all 4 speeds manually.
Please proceed as follows to adjust the fan speed:
ü
The device is switched on.
1. Select the desired fan speed by pressing the
speed
button (
21
).
ð
The
speed
LED (
20
) of stage 1, 2, 3 or 4 is illuminated.
Setting the timer
You can activate the automatic switch-off function after a preset
number of hours by means of the timer.
The number of hours can be set to 1 h, 2 h, 4 h or 8 h.
Automatic switch-off
ü
The device is switched on.
1. Press the
timer
button (
19
) until the desired number of
hours is shown on the
hours
LED (
18
).
ð
The timer setting equals the desired number of hours.
ð
The device switches off automatically after the set
number of hours has elapsed.
Note regarding automatic switch-off:
•
Pressing the on/off button (
22
) deactivates the automatic
switch-off function.
Ionization
With this function, the room air is not only cleaned by means of
the HEPA carbon filter, but additionally by means of negative
ions. The released ions remove pollen, dust, viruses and
bacteria from the room air.
The function can be set in addition in all operating modes.
1. Press the ionization button (
13
) to activate the ionization
function.
ð
The
ionization
LED (
12
) is illuminated.
ð
The device releases ions and cleans the air.
2. Press the
Ionization
button (
13
) again to deactivate the
ionization function.
ð
The ionization LED (
12
) goes out.
Switching the locking function on or off
The locking function prevents the buttons on the control panel
from being used.
Please proceed as follows to lock the control panel:
1. Simultaneously press the
speed
button (
21
) and the
Timer
button (
19
) for one second.
ð
After 3 seconds, an acoustic signal is emitted.
ð
The locking function is activated.
ð
The buttons on the control panel cannot be used.
ð
The
lock
LED (
10
) is illuminated.
2. Press the
speed
button (
21
) and the
timer
button (
19
)
for 3 seconds again to deactivate the function.
ð
The device switches back to the previous operating
mode.
Memory function
If you switch the device back on from standby mode, the
settings selected for the operating mode and fan speed are
saved.
In the event of short power failures, the device does not
memorize the settings. When switched on, the device will start
in
ventilation
mode in this case.