background image

EN

5

air cleaner AirgoClean® 150 E

Transport and storage

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Transport

To make the device easier to transport, it is fitted with a carry
handle.

Before

 transporting the device, observe the following:

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Do not use the power cable to drag the device.

After

 transporting the device, observe the following:

Set up the device in an upright position after transport.

Storage

When the device is not being used, observe the following
storage conditions:

Dry and protected from frost and heat

In an upright position where it is protected from dust and
direct sunlight

With a cover to protect it from invasive dust, if necessary

Assembly and start-up

Scope of delivery

1 x Device

1 x prefilter with integrated HEPA carbon filter

1 x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power

cable is not damaged and that you do not damage it during
unwinding.

Start-up

The HEPA carbon filter is pre-installed.

Note

Remove the plastic cover from the HEPA carbon filter.
To do so, please proceed as described in the chapter
Changing the HEPA carbon filter.

When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical data.

A

B

C

C

D

Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.

Only put up the device in an upright, stable position on firm
ground.

Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.

Make sure that extension cables are completely unrolled.

Position the device near the source of air contamination.

When positioning the device, keep a sufficient distance to
heat sources.

Make sure that no curtains or other objects interfere with
the air flow.

Make sure that the air inlet and outlet are not obstructed.

Connecting the power cable

Insert the mains plug into a properly fused mains socket.

Содержание AIRGOCLEAN 150 E

Страница 1: ...TRT BA AIRGOCLEAN 150E TC2020 52 002 EN AIRGOCLEAN 150 E EN OPERATING MANUAL AIR CLEANER ...

Страница 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental...

Страница 3: ...ose of replaced filters properly especially after filtering substances hazardous to health Never use the device as storage place or footstep Never select automatic mode if the device is used for virus filtration Intended use Use the device for cleaning the air in interior spaces only whilst adhering to the technical data and safety instructions Improper use Do not place the device on wet or floode...

Страница 4: ...pollen dust mite residue mould fungus spores and other allergens from the air The integrated prefilter made of synthetic fibre filters out large dust particles before the air flows into the HEPA filter The integrated carbon filter with activated carbon also removes odours from the air The HEPA carbon filter is effective against house dust pet allergens cigarette smoke smog and particles which can ...

Страница 5: ...ove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up The HEPA carbon filter is pre installed Note Remove the plastic cover from the HEPA carbon filter To do so please proceed as described in the chapter Changing the HEPA carbon filter When positioning the device observe the minimum distance from walls...

Страница 6: ...n 1 h 2 h 4 h 8 h 20 Speed LED Indication of the selected fan speed Stage 1 low Stage 2 mid Stage 3 high Stage 4 turbo 21 Speed button Setting the fan speed in 4 stages 22 On Off button Switching the device on and off Switching the device on Once you have completely installed the device as described in the Start up chapter you can switch it on When the power cable has been connected the control pa...

Страница 7: ...matic switch off function after a preset number of hours by means of the timer The number of hours can be set to 1 h 2 h 4 h or 8 h Automatic switch off ü The device is switched on 1 Press the timer button 19 until the desired number of hours is shown on the hours LED 18 ð The timer setting equals the desired number of hours ð The device switches off automatically after the set number of hours has...

Страница 8: ...ired clean or replace the prefilter with integrated HEPA carbon filter The filter LED 11 is illuminated Clean or replace the prefilter with integrated HEPA carbon filter see chapter Operation and chapter maintenance The air outlet is obstructed Make sure that the air outlet is not blocked Remove any loose objects from the air outlet The HEPA carbon filter s plastic cover was not removed before ins...

Страница 9: ...ent screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the filter for dirt and foreign objects and clean or replace if necessary Replacing the prefilter w...

Страница 10: ...um cleaner 5 Put the air filter back in Cleaning and replacing the prefilter with integrated HEPA carbon filter Note Do not operate the device without an inserted prefilter with integrated HEPA carbon filter Note The HEPA carbon filter is not washable Only the integrated prefilter may be cleaned Do not use water or liquid cleaning agents to clean the 3 1 filter Note The lifetime of the prefilter w...

Страница 11: ...to be used remove it from the plastic cover 5 Reinsert the prefilter with integrated HEPA carbon filter 23 into the device Make sure that the strips 24 of the filter are positioned on the outside 23 24 6 Put the air inlet 6 back on the device 6 7 Press the ION button 13 for two seconds to reset the Filter LED 11 Cleaning the air quality sensor The air quality sensor 5 has to be cleaned once it is ...

Страница 12: ...put 32 W Sound pressure level 52 dB A Nominal current 0 1 A Dimensions length x width x height 387 x 247 x 571 mm Minimum distance to walls and other objects A top B rear C side D front 30 cm 30 cm 30 cm 30 cm Weight 7 kg Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at th...

Страница 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: