moisture indicator BM31

Technical data

Parameter

Value

Model

BM31

Measurement principle: Dielectric

Measuring range:

0 to 100 digits

Measuring range
resolution:

1 digit

Penetration depth

5 to 40 mm

Operating temperature: 0 to 40 °C

Storage temperature:

-20 to 70 °C

Power supply:

1 x 9 V battery

Automatic switch-off:

after approx. 30 seconds of non-use

Weight:

190 g

Dimensions:
(height x width x depth) 190 x 55 x 32 mm

Scope of delivery

1 x Device 

BM31

1 x 9 V battery

1 x Quick guide

Transport and storage

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Transport

For transporting the device use a suitable bag to protect it from
external influences.

Storage

When the device is not being used, observe the following
storage conditions:

dry and protected from frost and heat

protected from dust and direct sunlight

the storage temperature complies with the values specified
in the Technical data

Remove the batteries from the device.

Operation

Inserting the batteries

Insert the supplied battery before first use.

Note

Make sure that the surface of the device is dry and the
device is switched off.

1. Open the battery compartment at the rear of the device by

sliding down the cover (14).

2. Use the battery clip (15) to connect the 9 V battery with

correct polarity.

3. Place the battery with the battery clip into the battery

compartment.

4. Slide the cover (14) back onto the battery compartment.

14

15

Switching the device on

Info

Please note that moving from a cold area to a warm
area can lead to condensation forming on the device's
circuit board. This physical and unavoidable effect can
falsify the measurement. In this case, the display
shows either no measured values or they are incorrect.
Wait a few minutes until the device has become
adjusted to the changed conditions before carrying out
a measurement.

1. Press the on/off switch (8).

ð

The display switches on.

ð

The device starts the calibration.

Содержание 3510205031

Страница 1: ...TRT BA BM31 TC220926TTRT02 002 EN BM31 EN ORIGINAL INSTRUCTIONS MOISTURE INDICATOR ...

Страница 2: ...vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference The device is supplied with warning signs Prior to initial start up make sure to paste the corresponding warning signs in your local language ov...

Страница 3: ...ot use the device in potentially explosive atmospheres for measurements in liquids or at live parts Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications People who use this device must have read and understood the instructions especially the Safety chapter Residual risks Warning of electrical voltage There is a risk of a short circuit due to li...

Страница 4: ...ant measuring spots to extract material for the CM measurement A max min function is available for the assessment of the measurements The measuring device comes equipped with a selectable display illumination When not in use an automatic switch off saves the battery Device depiction 1 2 3 4 No Designation 1 Sensor 2 Battery compartment with cover 3 Operating elements 4 Display Operating elements 5...

Страница 5: ... direct sunlight the storage temperature complies with the values specified in the Technical data Remove the batteries from the device Operation Inserting the batteries Insert the supplied battery before first use Note Make sure that the surface of the device is dry and the device is switched off 1 Open the battery compartment at the rear of the device by sliding down the cover 14 2 Use the batter...

Страница 6: ... 1 Press the Lamp button 5 ð The background illumination is activated 2 Press the Lamp button 5 again ð The background illumination is deactivated Switching the device off Info The device automatically switches off after approx 30 seconds of non use Please proceed as follows for manual switch off 1 Press the on off switch 8 ð The device is switched off Dielectric measurements The measuring device ...

Страница 7: ...hich then simulates high moisture values Consequently a too high measured value will be displayed If the material to be measured contains metal e g nails screws lines pipes etc and is situated within the sensor s measuring field the measured value skyrockets due to intense reflections From visual inspection it is not always apparent whether there are any electrically conducting substances inside t...

Страница 8: ...2 19 EU It states that this device must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub...

Страница 9: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: