Selecting the measuring mode

After switch-on, the device displays the temperature (

TEMP

indication, 20).
The following measuring modes are available:

Measuring mode

Description

TEMP

Ambient temperature

RH

Relative humidity

HI

Heat index

DP

Dew point temperature

WB

Wet-bulb temperature

WBGT

Wet-bulb globe temperature

 index

(

WBGT

 index)

Please proceed as follows to set the measuring mode:
1. Repeatedly press the 

Mode

 button (3) until the desired

measuring mode is displayed.

Setting the HOLD function

1. Press the 

Hold

 button (4).

ð

The current value will be held.

2. Press the 

Hold

 button (4) again.

ð

The display again indicates the current measured value.

Setting the MAX/MIN/AVG function

Info

These functions can only be used in the 

TEMP

 and 

RH

measuring modes.

You can view the highest, lowest or average temperature or
relative humidity value from the current measuring interval.
Please proceed as follows:
1. Briefly press the Power button (5).

ð

The 

MAX

 indication (8) appears on the display.

ð

The display now indicates the highest temperature or
humidity value measured since the device was
switched on in the selected measuring mode.

2. Press the Power button (5) again.

ð

The 

MIN

 indication (9) appears on the display.

ð

The display now indicates the lowest temperature or
humidity value measured since the device was
switched on.

3. Press the Power button (5) again.

ð

The 

AVG

 indication (10) appears on the display.

ð

The display now indicates the average temperature and
humidity values measured since the device was
switched on.

4. Press the Power button (5) again.

ð

The display again indicates the current measured value.

Changing the unit °C / °F

The default setting for the temperature unit is °C.
Please proceed as follows to change the temperature unit:
1. Switch off the device by pressing the Power button (5) and

holding it for approx. 5 s.

2. Simultaneously press the power button (5) and the 

Mode

button (3).

ð

The currently selected unit °C or °F is displayed.

3. Press the 

Mode

 button (3) to change the unit.

4. Afterwards repeatedly press the Power button (5) until the

measured temperature value is displayed again.

Содержание 3.510.205.008

Страница 1: ...TRT BA BC25 TC 001 EN BC25 EN OPERATING MANUAL THERMOHYGROMETER ...

Страница 2: ... of conformity via the following link BC25 http hub trotec com id 39585 Legal notice This release replaces all previous versions No part of this publication may be reproduced without written permission from Trotec GmbH Co KG The same applies for electronically processing duplicating or spreading the publication Subject to technical changes All rights reserved Trademarks are used without guarantee ...

Страница 3: ...warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning ...

Страница 4: ...determined A configurable alarm function issues a warning as soon as a certain value is exceeded When not in use an automatic switch off saves the battery Heat index The heat index also referred to as humidex is an indicator developed in the 1970s by the American Steadman It describes the combined effect of temperature and high humidity levels on the human body The higher the relative humidity the...

Страница 5: ...in walled matt black globe reacting to the infrared heat radiation emitted by the sun When calculating the WBGT in indoor areas or outdoor areas exposed to negligible amounts of sunlight it can be assumed that the radiation temperature has practically no influence In this case the globe temperature is assumed to be identical with the ambient temperature Therefore the WBGT index is another indicato...

Страница 6: ...0 C 80 RH non condensing Automatic switch off after approx 15 minutes Power supply 1 x CR2032 battery Scope of delivery 1 x Thermohygrometer BC25 1 x CR2032 battery 1 x Quick guide WBGT index In the course of sports events for instance both the WBGT and the HI index are increasingly used as an indication for a potential physical stain and associated hazards Colour of warning flag Risk Effect WBGT ...

Страница 7: ...40 42 43 44 45 47 48 49 50 30 30 32 33 34 35 36 37 39 40 41 42 43 45 46 47 48 29 29 30 31 32 33 35 36 37 38 39 40 41 42 43 45 46 28 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 27 27 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 26 26 26 27 28 29 30 31 32 33 34 34 35 36 37 38 39 25 25 25 26 27 27 28 29 30 31 32 33 34 34 35 36 37 24 24 24 24 25 26 27 28 28 29 30 31 32 33 33 34 35 23 23 23 23 24 2...

Страница 8: ...y compartment by unscrewing it with a suitable object e g a coin 2 Remove the battery cover 3 Insert the battery 1 x CR2032 battery into the battery compartment with correct polarity 4 Screw the cover back on the battery compartment Switch on and measurements Note Note that moving from a cold area to a warm area can lead to condensation forming on the device s circuit board This physical and unavo...

Страница 9: ...ower button 5 ð The MAX indication 8 appears on the display ð The display now indicates the highest temperature or humidity value measured since the device was switched on in the selected measuring mode 2 Press the Power button 5 again ð The MIN indication 9 appears on the display ð The display now indicates the lowest temperature or humidity value measured since the device was switched on 3 Press...

Страница 10: ... alarm function for the WBGT index is activated the alarm value can now be determined 9 Press the Mode button 3 to increase the alarm value in steps of 0 1 Press and hold the Mode button 3 to increase the value faster or in larger steps 10 Press the Power button 5 to save the alarm value for the WBGT index ð The display again indicates the current measured value ð The selected settings are saved A...

Страница 11: ... waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our websit...

Отзывы: