background image

1

EN

Operating manual – thermohygrometer BC25

Table of contents

Notes regarding the operating manual................................. 1

Safety ..................................................................................... 2

Information about the device................................................ 3

Transport and storage........................................................... 7

Operation ............................................................................... 7

Errors and faults.................................................................... 9

Maintenance and repair ...................................................... 10

Disposal ............................................................................... 10

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Notice

This signal word indicates important information 
(e.g. material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

BC25

http://hub.trotec.com/?id=39585

Legal notice

This release replaces all previous versions. No part of this
publication may be reproduced without written permission from

Trotec GmbH & Co. KG

. The same applies for electronically

processing, duplicating or spreading the publication. Subject to
technical changes. All rights reserved. Trademarks are used
without guarantee that they may be used freely and primarily
following the spelling of the manufacturer. Product names are
registered.
Changes to construction in the interests of constant
improvements to the product, as well as changes to the shape
and colour are reserved.
The scope of delivery may vary from product images. This
document was created with all due care.

Trotec GmbH & Co. KG

 accepts no liability whatsoever for

possible mistakes or omissions.
The only party responsible for determining valid measured
results, drawing conclusions and deriving actions is the user.

Trotec GmbH & Co. KG

 accepts no claims of warranty for the

correctness of the determined measured values or measured
results.
Further, 

Trotec GmbH & Co. KG

 accepts no liability whatsoever

for possible mistakes or damage which have been caused by
utilising the determined measured results.
© 

Trotec GmbH & Co. KG

Содержание 3.510.205.008

Страница 1: ...TRT BA BC25 TC 001 EN BC25 EN OPERATING MANUAL THERMOHYGROMETER ...

Страница 2: ... of conformity via the following link BC25 http hub trotec com id 39585 Legal notice This release replaces all previous versions No part of this publication may be reproduced without written permission from Trotec GmbH Co KG The same applies for electronically processing duplicating or spreading the publication Subject to technical changes All rights reserved Trademarks are used without guarantee ...

Страница 3: ...warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning ...

Страница 4: ...determined A configurable alarm function issues a warning as soon as a certain value is exceeded When not in use an automatic switch off saves the battery Heat index The heat index also referred to as humidex is an indicator developed in the 1970s by the American Steadman It describes the combined effect of temperature and high humidity levels on the human body The higher the relative humidity the...

Страница 5: ...in walled matt black globe reacting to the infrared heat radiation emitted by the sun When calculating the WBGT in indoor areas or outdoor areas exposed to negligible amounts of sunlight it can be assumed that the radiation temperature has practically no influence In this case the globe temperature is assumed to be identical with the ambient temperature Therefore the WBGT index is another indicato...

Страница 6: ...0 C 80 RH non condensing Automatic switch off after approx 15 minutes Power supply 1 x CR2032 battery Scope of delivery 1 x Thermohygrometer BC25 1 x CR2032 battery 1 x Quick guide WBGT index In the course of sports events for instance both the WBGT and the HI index are increasingly used as an indication for a potential physical stain and associated hazards Colour of warning flag Risk Effect WBGT ...

Страница 7: ...40 42 43 44 45 47 48 49 50 30 30 32 33 34 35 36 37 39 40 41 42 43 45 46 47 48 29 29 30 31 32 33 35 36 37 38 39 40 41 42 43 45 46 28 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 27 27 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 26 26 26 27 28 29 30 31 32 33 34 34 35 36 37 38 39 25 25 25 26 27 27 28 29 30 31 32 33 34 34 35 36 37 24 24 24 24 25 26 27 28 28 29 30 31 32 33 33 34 35 23 23 23 23 24 2...

Страница 8: ...y compartment by unscrewing it with a suitable object e g a coin 2 Remove the battery cover 3 Insert the battery 1 x CR2032 battery into the battery compartment with correct polarity 4 Screw the cover back on the battery compartment Switch on and measurements Note Note that moving from a cold area to a warm area can lead to condensation forming on the device s circuit board This physical and unavo...

Страница 9: ...ower button 5 ð The MAX indication 8 appears on the display ð The display now indicates the highest temperature or humidity value measured since the device was switched on in the selected measuring mode 2 Press the Power button 5 again ð The MIN indication 9 appears on the display ð The display now indicates the lowest temperature or humidity value measured since the device was switched on 3 Press...

Страница 10: ... alarm function for the WBGT index is activated the alarm value can now be determined 9 Press the Mode button 3 to increase the alarm value in steps of 0 1 Press and hold the Mode button 3 to increase the value faster or in larger steps 10 Press the Power button 5 to save the alarm value for the WBGT index ð The display again indicates the current measured value ð The selected settings are saved A...

Страница 11: ... waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our websit...

Отзывы: