Trotec 1050000403 Скачать руководство пользователя страница 11

EN

11

convector TCH 1510 E / TCH 2510 E

Frost monitor mode

In 

frost monitor mode

 ( ) the devices heats automatically if the

room temperature is below 5 °C. This temperature cannot be
changed.

ü

The device is switched on and the 

On /off

 button (

9

) has

been actuated.

1. Press the 

Mode

 button (

14

) until the   symbol (

7

) appears

on the control panel.

2. Press the 

OK

 button (

11

) to set the frost monitor mode.

3. Press the 

Increase value

 button (

12

) to set the frost

monitor mode to 

ON

.

4. Press the 

OK

 button (

11

) to confirm the selection.

ð

The device heats as soon as the room temperature is
below 5 °C. It stops heating as soon as the room
temperature exceeds 5 °C.

ð

The   symbol (

7

) appears on the control panel.

Please proceed as follows to switch off the frost monitor mode:

ü

The frost monitor mode is switched on.

1. Press the 

Mode

 button (

14

) until the   symbol (

7

) appears

on the control panel.

2. Press the 

OK

 button (

11

).

3. Press the 

Increase value

 button (

12

) to set the frost

monitor mode to 

OFF

.

4. Press the 

OK

 button (

11

) to confirm the selection and to

exit the frost monitor mode.

ð

The   symbol (

7

) no longer appears on the control

panel.

Open window detection

The 

open window detection

 is deactivated by default. Please

proceed as follows to activate the function:

1. Press the 

OK

 button (

11

).

2. Press the 

Increase value 

 button (

12

).

3. Press the 

On/off

 button (

9

) to confirm the function.

ð

If the temperature quickly decreases by 5 °C, the
current operating mode is quit instantaneously.

ð

The symbols   (

7

) and   (

7

) are displayed on the

control panel.

Switching the locking function on and off

The locking function prevents the buttons on the control panel
from being used.
Please proceed as follows to lock the control panel:

1. Press the 

Mode

 button (

14

) until the   symbol (

7

) appears

on the control panel.

2. Press the 

OK

 button (

11

) to lock the control panel

ð

After 3 seconds, an acoustic signal is emitted.

ð

The locking function is activated.

ð

The buttons on the control panel cannot be used.

3. Press the 

Mode

 button (

14

) again to switch the swing

function off.

ð

The device switches back to the previous operating
mode.

Operating hours display

Proceed as follows to display the expired operating hours:

1. Press the 

Mode

 button (

14

) until the   symbol (

7

) appears

on the control panel.

2. Press the 

OK

 button (

11

) to display the expired operating

hours.

ð

Only full operating hours (

10

) are displayed.

3. Press the 

Mode

 button (

14

) or the   button (

7

) to exit the

preview.

ð

The operating hours are indicated in full hours. The
example shows 1,503 operating hours.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

1. Switch off the device by pressing the 

On/off

 button (

9

).

ð

The device is now in standby mode.

2. Set the On/off switch (

4

) to position 

O

 to switch the device

off.

3. Hold onto the mains plug while pulling the power cable out

of the mains socket.

4. Allow the device to cool down sufficiently.
5. Clean the device according to the Maintenance chapter.
6. Store the device according to the Storage chapter.

Содержание 1050000403

Страница 1: ...TRT BA TCH1510E TCH2510E TC2020 45 002 EN TCH 1510 E TCH 2510 E EN OPERATING MANUAL CONVECTOR EN This product is only suitable for well insulated spaces or occasional use ...

Страница 2: ...k TCH 1510 E https hub trotec com id 44797 TCH 2510 E https hub trotec com id 44798 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save ...

Страница 3: ...ert the mains plug into a properly fused mains socket Observe the device s power input cable length and intended use when selecting extensions to the power cable Completely unroll extension cables Avoid electrical overload Before carrying out maintenance care or repair work on the device remove the mains plug from the mains socket Hold onto the mains plug while doing so Switch the device off and d...

Страница 4: ... etc above or directly in front of the device In order to avoid overheating and fire hazards the heater must not be covered Residual risks Warning of electrical voltage Work on the electrical components must only be carried out by an authorised specialist company Warning of electrical voltage Before any work on the device remove the mains plug from the mains socket Do not touch the mains plug with...

Страница 5: ...aces The device generates heat by means of an electric heating element The air surrounding the heating element is heated The heated air rises through the air outlet and thus creates a natural suction that makes the cold room air flow into the device The device is equipped with an integrated temperature sensor which controls the heating depending on the current and the desired room temperature The ...

Страница 6: ...y When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary Place no further devices or objects on top of the device to prevent it from being damaged Assembly and installation Scope of delivery 1 x Convector 2 x...

Страница 7: ...ositions for the bore holes on the wall Observe the minimum distances specified in the technical data 2 Drill the holes into the wall at the marked positions 3 Insert appropriate wall plugs into the bore holes depending on the type of wall Position the holder on the wall as indicated and attach the holder in place with the 4 screws 4 Hook the lower part of the device into the lower part of the hol...

Страница 8: ...ntact the customer service Set the device up in an upright and stable position Do not create tripping hazards when laying the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are completely unrolled Make sure that no curtains or other objects interfere with the air flow Do not position the device...

Страница 9: ...re can be preset Operating hours display Screen is locked 8 Temperature indication Indicates the current room temperature 9 On off button Switching the device on or off 10 Time display Displays the current time the set time of the timer or the operating hours 11 OK button Confirm selection 12 Increase value button Setting the desired room temperature 0 C to 50 C or the timer run time 1 min to 24 h...

Страница 10: ...ecrease value button 13 to adjust the temperature setting ð The set temperature 8 is shown flashing on the control panel 3 Press the OK button 11 to start the automatic mode ð The room temperature display 8 now initially indicates the current room temperature ð The device heats and the symbol 7 is displayed on the control panel Week mode Note To activate the week mode you have to preset all weekda...

Страница 11: ...by 5 C the current operating mode is quit instantaneously ð The symbols 7 and 7 are displayed on the control panel Switching the locking function on and off The locking function prevents the buttons on the control panel from being used Please proceed as follows to lock the control panel 1 Press the Mode button 14 until the symbol 7 appears on the control panel 2 Press the OK button 11 to lock the ...

Страница 12: ...l company The air current is reduced Check the air inlet and outlet Make sure that air inlet and outlet are not obstructed Remove any dirt Observe the minimum distance from walls or other objects according to the technical data Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on The device still does not operate correctly after these checks Please...

Страница 13: ...220 240 V 50 60 Hz Power consumption 1500 W 2500 W Nominal current consumption 6 5 A 10 A Cable length 1 8 m 1 8 m Plug type CEE 7 7 CEE 7 7 Protection class IP 24 IP 24 Dimensions depth x width x height 260 x 690 x 535 mm 280 x 1250 x 525 mm Minimum distances from walls or other objects only in stationary operation A top B rear C side D front 100 cm 100 cm 100 cm 100 cm 100 cm 100 cm 100 cm 100 c...

Страница 14: ...e control with room and or outdoor temperature feedback NA NA Fan assisted heat output NA NA Type of heat output room temperature control Single stage heat output no room temperature control NO NO Two or more manual stages no room temperature control NO NO With mechanic thermostat room temperature control NO NO With electronic room temperature control NO NO With electronic room temperature control...

Страница 15: ...ality or local administration You can also find out about other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment authorised for your country The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms ...

Страница 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: