Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Make sure that the device is switched off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Care and maintenance must be performed on a regular basis to
ensure the proper functioning and failure-free operation of the
device.
The type and frequency of the maintenance tasks fundamentally
depends on the operating environment as well as on the
duration and type of use.
In the course of using the device, dust and moisture can
accumulate in or on the components which may compromise
functionality and efficiency.
In rooms with a high volume of dust and dirt or after fire
damage restorations (high moisture level) you should already
check the need for maintenance after only a few applications.
In dry surroundings e.g. hotels or as part of car valeting one can
assume a maintenance rate of several months.

Criteria for determining the maintenance interval

Device operation takes place:

frequently and several hours at a time

on many days per month

in excessively dirty surroundings

in humid rooms

Regardless of the described operating conditions you should
perform maintenance work if one or more of the following signs
become apparent:

increased noise level during operation of the fan

heavily contaminated air filter

dirty electrode (recognizable by: The hissing sound
produced during ozone generation dies away.)

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.

Cleaning

In addition to the inspection of the device and its components
for proper condition you should also ensure thorough cleaning
as part of the regular maintenance activities. To do so, please
proceed as described below.

Air filter

1. Loosen the screws at the rear of the device.

2. Remove the cover of the air filter.

3. Remove the air filter.
4. Clean the air filter using soapsuds.
5. Insert the air filter into the device when it is dry.

Содержание 1.180.000.020

Страница 1: ...TRT BA AIRGOPRO8 TC220502TTRT01 001 EN AIRGOPRO 8 EN ORIGINAL INSTRUCTIONS ODOUR NEUTRALISER...

Страница 2: ...n the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or...

Страница 3: ...ke sure that the suction side is kept free of dirt and loose objects This odour neutraliser generates very small amounts of ozone max 0 05 ppm sqm which are harmless to health Reduce the ozone output...

Страница 4: ...sk of injury caused by inhalation of ozone During the air purification cycle small amounts of ozone O3 may be produced If necessary gradually reduce the production or take the device out of operation...

Страница 5: ...the treatment the oxygen contained in the room air is converted so that existing odour molecules are broken down by means of oxidation The device also produces very small amounts max 0 05 ppm m3 of oz...

Страница 6: ...pletely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up When positioning the device observe th...

Страница 7: ...time 14 Multiplier display Indicates the set multiplier 15 Rotary switch for scale Setting the time scale 16 Rotary switch for multiplier Setting the multiplier in the following increments 0 0 5 0 1 0...

Страница 8: ...ry switch for the multiplier 16 to determine whether the indicator scale 13 shall be used for 5 or 50 time units After the expiration of this time the device will switch off automatically The timer is...

Страница 9: ...set time to elapse before making a new adjustment 8 Air out the room after each interval and after each readjustment The temperature is also a crucial factor for successful treatment Heat increases t...

Страница 10: ...age Check the on site fusing Switch the fuse back on or have a defective fuse replaced by a specialist company Wait for 10 minutes before restarting the device If the device is not starting have the e...

Страница 11: ...screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects...

Страница 12: ...ng the maintenance interval Device operation takes place frequently and several hours at a time on many days per month in excessively dirty surroundings in humid rooms Regardless of the described oper...

Страница 13: ...ctrode The electrode may be cleaned whilst built in 1 Prior to cleaning check the electrode for cracks or breakage Damaged components must not be used 2 Clean the electrode using a lint free dry or da...

Страница 14: ...14 EN odour neutraliser AirgoPro 8 Circuit diagram...

Страница 15: ...itions of the components mentioned in these instructions No Designation No Designation 1 Operating hours counter 8 Intensity level controller 2 Connection plug incl mains plug 9 On off mains switch 3...

Страница 16: ...ind out about other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equ...

Страница 17: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: