Connecting Power
Tropos 5210 MetroMesh Router Installation Guide
33
Note
The Tropos 5210 MetroMesh router is equipped with additional AC surge protection and dual
fuse branch circuit protection. Additional ISA branch circuit protection is not required in the
upstream power distribution.
Figure 19 Connecting the AC Power Cable
Connecting to Streetlight Power (Category C)
The power connections for Category C streetlight power are shown in
Figure 20
. Use the 3-
prong NEMA twist-lock adapter with twist-lock style photoelectric controls for outdoor lighting
commonly used by utilities. The NEMA twist-lock adapter can be used only with UL 773 listed
outdoor lighting controls rated for and operated at 100-480 VAC 50/60 Hz.
Warning
Be extremely careful when connecting to Category C streetlight power.
Figure 20 Connecting Streetlight Power
trp_107
Tighten nut to secure
power connection
AC power from
power adapter
on photosensor
AC power from
power adapter
on photosensor