tropitone 401154FTBL Скачать руководство пользователя страница 4

R9TFIRETABLE 

Page 4 of 12 

         Rev. D11MAR14 

DANGER

 

Do  not  install  this  product  under  any  type  of  covering,  including  overhangs,  patio 
covers,  umbrellas,  cabanas,  tree  limbs  or  branches.  The  risk  of  fire,  inhalation  of 
fumes,  and  exposure to excessive  heat  increases  greatly  if  this  product  is  installed 
under any type of covering, which could result in personal injury, damage to property 
or death. 

 
IMPORTANT

 

 

It is important that the gas line feeding the fire pit if piped is a minimum of ¾” 
or larger, based on the distance from the fuel source. 

 

  Choose a location which has proper drainage. 

 

 

Choose a location with a minimum clearance of 48” from other structures. 

 

WARNING

 

It is the responsibility of the person installing this unit to test and verify that there are 
no  gas  leaks  after  assembly  is  completed.  NEVER  test  for  gas  leaks  with  a  flame. 
Use only a gas leak detector or gas reactant. 

 

WARNING

 

This unit is fully plumbed, ready for operation after leg assembly. Should you need to 
replace any item which is plumbed, or during conversion to operate with Natural gas, 
use only joint compound or tape that is approved for use with all types of gas. Apply 
to all male pipe fittings only. DO NOT use on FLARED fittings. Be sure all joints are 
tightened securely before lighting. 

 

WARNING

 

Installation and repair should be done by a qualified service person. The appliance 
should be inspected before use and at least annually by a qualified service person. 
More  frequent  cleaning  may  be  required  as  necessary.  It  is  imperative  that  control 
compartment,  burners,  and  circulating  air  passageways  of  the  appliance  be  kept 
clean. 

DANGER

 

When using glass media in a Fire Table, use only approved fire glass, and 
insure that there is only enough to leave the burner holes exposed. Applying 
over ½” of any media over the burner can create back pressure which can 
result in gas leakage from the air mixer, or settling of unburned gas which may 
leak below the burner pan and ignite. This may result in a dangerous situation 
which can result in personal injury, damage to property or death.

 

 

DANGER

 

Do  not  use  this  appliance  if  any  part  has  been  under  water.  Immediately  call  a 
qualified  service  technician  to  inspect  the  appliance  and  replace  any  part  of  the 
control system and any gas control which has been under water. 

 
 
 
Before you can enjoy your new Fire Table, you must assemble the table legs and leg brace to the 
unit.  Instructions  for  your  table  type  can  be  found  in  the  Tropitone  KD  Table  Assembly  guide 
supplied  with  this  product,  or  on  the  web  at  www.tropitone.com.  You  must  also  connect  a  Liquid 
Petroleum (LP) gas tank (sold separately).  
 

Inside  the  Access  door,  this  unit  is  provided  with  4  internal  connections 
for  use  with  1  lbs.  disposable  LP  tanks.  Your  Fire  Table  is  designed  to 
operate with 1, 2, 3, or 4 of the 1 lbs. tanks connected. They do not need 
to be connected in any particular order, or to any particular one of the 4 
ports supplied. 

 

Содержание 401154FTBL

Страница 1: ...sult in property damage Read these installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors or liquids in or near this or any other appliance An LP Liquefied Petroleum tank that is not connected for use shall not be stored in or near this or any other appliance DANGER If you smell gas...

Страница 2: ...ity to ensure this product has been installed in accordance with the local codes applicable and that the end user has been educated on the safe and proper operation of the unit WARNING Tropitone recommends that all gas products installed in the USA and CANADA be serviced and maintained by professionals that are certified by the National Fireplace Institute NFI as a NFI Gas Specialist or by the Woo...

Страница 3: ...for outdoor use only Never install or operate indoors Burning gas both Natural and LP produces fumes which can be dangerous if inhaled Always insure there is proper ventilation when using any fire products DANGER All Fire Tables are designed and intended for outdoor use only Never install or operate indoors Burning gas both Natural and LP produces very high temperatures Always insure all combustib...

Страница 4: ...hould be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necessary It is imperative that control compartment burners and circulating air passageways of the appliance be kept clean DANGER When using glass media in a Fire Table use only approved fire glass and insure that there is only enough to leave the burner holes exposed Applyin...

Страница 5: ...the table is available WARNING The LP Gas tank or cylinder used must comply with the following requirements Use of other tanks or cylinders which do not meet these requirements may create an unsafe condition which could cause injury or death to you or damage to your personal property including the risk of fire or explosion The tank or cylinder used must be 1 Constructed and marked in accordance wi...

Страница 6: ...rer WARNING Inspect the hose and tank connector before each use to insure there is no damage caused by rodents weather or other conditions NEVER use any Fire Table which has any components including the gas hose or gas tank connector damaged in any way If you find any damage turn off the valve on the gas tank and call a licensed repair technician to replace damaged components Replace any damaged i...

Страница 7: ...not install without a regulator which will limit your fuel supply to 5 inches of water column CAUTION Use a joint compound or thread tape approved for the type of gas this appliance is intended to use on all male threads EXCEPT compression threads Never apply thread tape or compound to compression threads Beneath the Burner tray locate the Gas Air Mixer in the plumbing Remove the LP Gas Air Mixer ...

Страница 8: ...al property The deeper your lava rock or glass the more risk of reducing or smothering the flame from the burner Lava Rock Only Application 1 Install your Fire Table per instructions 2 Apply lava rock ONLY deep enough to cover burner no more than 1 2 above burner 3 Blow Out Box Do not cover vents with lava rock leave open Do not allow any rock to block flame opening 4 Blowout Box Do not cover blow...

Страница 9: ...igniter by depressing switch in short bursts until pilot lights 5 Once lit release switch for spark igniter while continuing to depress valve knob for 20 seconds 6 Turn knob counter clockwise left to light main burner NOTE If fails to light rotate knob to center position wait 5 minutes for gas to clear repeat Steps 3 6 If pilot goes out repeat Steps 3 6 7 Once Fire Table has ignited DO NOT leave u...

Страница 10: ...lve x MPT R18VL103 9 LP Tank Connector FPT x 1 20 R18CO113 10 Gas Flex Line 24 x 1 2 R15SP100 11 Compression Fitting 1 8 R15CO104 12 Gas Valve R18VL100 13 Nut Retaining M1 for Gas Valve R02NU501 14 Knob Black for Gas Valve R02MS102 15 Gas Plumbing Support Weldment W401158SGV 16 Elbow 3 8 MPT x 3 8 FPT R15CO100 17 Ignition Switch With Gasket R19SW100 18A Spark Igniter Power Supply Housing Sold as S...

Страница 11: ...less Steel R02NU500 6 Burner Tray Square 18 R15MS301 Burner Tray Round 18 not shown R15MS300 7 Nipple 1 2 Stainless Steel R15CO106 8 1 2 x 3 8 Reducing Bushing R15CO108 9 3 8 LP Gas Air Mixer 40KBTU R18VL104 10 Elbow 3 8 MPT x 3 8 FPT R15CO100 11 3 8 FPT TEE R15CO109 12 3 8 Flare x 1 2 MIPT R18CO107 13 3 8 x 1 8 Reducing Bushing R15CO110 14 Solid Hex Socket Plug W Thread Sealant R02SC443 15 Electr...

Страница 12: ...able has been tested and approved in accordance with ANSI Z21 97 by ICC ES Listing No PMG 1114 Tropitone Furniture Co Inc 5 Marconi Irvine Ca 92618 949 951 2010 www tropitone com 1401 Commerce Blvd Sarasota Fl 34243 Tropitone Furniture Co Inc 2013 12 13 ...

Отзывы: