DANGER
Do not install this product under any type of covering, including overhangs, patio
covers, umbrellas, cabanas, tree limbs or branches. The risk of fire, inhalation of
fumes, and exposure to excessive heat increases greatly if this product is installed
under any type of covering, which could result in personal injury, damage to property
or death.
IMPORTANT
It is important that the gas line feeding the fire pit if piped is a minimum of ¾”
or larger, based on the distance from the fuel source.
Choose a location which has proper drainage.
Choose a location with a minimum clearance of 48” from other structures.
WARNING
It is the responsibility of the person installing this unit to test and verify that there are
no gas leaks after assembly is completed. NEVER test for gas leaks with a flame.
Use only a gas leak detector or gas reactant.
WARNING
This unit is fully plumbed, ready for operation after leg assembly. Should you need to
replace any item which is plumbed, or during conversion to operate with Natural gas,
use only joint compound or tape that is approved for use with all types of gas. Apply
to all male pipe fittings only. DO NOT use on FLARED fittings. Be sure all joints are
tightened securely before lighting.
WARNING
Installation and repair should be done by a qualified service person. The appliance
should be inspected before use and at least annually by a qualified service person.
More frequent cleaning may be required as necessary. It is imperative that control
compartment, burners, and circulating air passageways of the appliance be kept
clean.
DANGER
When using glass media in a Fire Table, use only approved fire glass, and
insure that there is only enough to leave the burner holes exposed. Applying
over ½” of any media over the burner can create back pressure which can
result in gas leakage from the air mixer, or settling of unburned gas which may
leak below the burner pan and ignite. This may result in a dangerous situation
which can result in personal injury, damage to property or death.
DANGER
Do not use this appliance if any part has been under water. Immediately call a
qualified service technician to inspect the appliance and replace any part of the
control system and any gas control which has been under water.
Before you can enjoy your new Fire Table, you must assemble the table legs and leg brace to the
unit. Instructions for your table type can be found in the Tropitone KD Table Assembly guide
supplied with this product, or on the web at www.tropitone.com. You must also connect a Liquid
Petroleum (LP) gas tank (sold separately).
Inside the Access door, this unit is provided with 4 internal connections
for use with 1 lbs. disposable LP tanks. Your Fire Table is designed to
operate with 1, 2, 3, or 4 of the 1 lbs. tanks connected. They do not need
to be connected in any particular order, or to any particular one of the 4
ports supplied.