tropitone 401154FTBL Скачать руководство пользователя страница 3

R9TFIRETABLE 

Page 3 of 12 

         Rev. D11MAR14 

DANGER

 

This product is not to be used as a starter for wood or any other combustible 
material. 

 

WARNING

 

It is the installer’s responsibility to ensure this product has been installed in 
accordance with all the local codes applicable. In the absence of local codes, please 
follow: 

 

  For Fixed Piping Systems: 

The National Fuel Gas Code, ANSI Z223.1/NFPA

 

54

 or 

the International Fuel Gas Code.

 

 

  For Electrical: The 

National Electrical Code, ANSI/NFPA 70.

 

 

WARNING

 

Use  only  the  gas  or  fuel  type  specified  for  this  unit.  See  the  label  inside  the  door. 
Verify  the  gas  or  fuel  is  correct  and  the  proper  pressure  available.  NEVER  use  an 
alternative fuel, including bio-fuel, ethanol, or any other fuel type with this unit. 

 
 

The proper pressure and gas type must be checked prior to installation

. A 1/8” NPT 

test port is provided at the burner assembly connection beneath the burner tray. 

 

  LP Gas: 

  Supply Pressure: Minimum 10

.0” WC (water column), Maximum 15.0”” WC 

  Outlet Pressure : Minimum 10.0

” WC, Maximum 12.0” WC 

 

  NATURAL Gas: 

  Supply Pressure: Minimum 5

.0” WC (water column), Maximum 9.0”” WC 

 

Outlet Pressure : Minimum 5.0” WC, Maximum 7.0” WC 

 
 

DANGER

 

All  Fire  Tables  are  designed  and  intended  for  outdoor  use  only.  Never  install  or 
operate  indoors.  Burning  gas  (both  Natural  and  LP)  produces  fumes  which  can  be 
dangerous  if  inhaled.  Always  insure  there  is  proper  ventilation  when  using  any  fire 
products. 

 

DANGER

 

All  Fire  Tables  are  designed  and  intended  for  outdoor  use  only.  Never  install  or 
operate  indoors.  Burning  gas  (both  Natural  and  LP)  produces  very  high 
temperatures.  Always  insure all combustible materials are kept far  enough away to 
prevent accidental ignition. 

 

IMPORTANT

  When selecting a location for this product, insure that there is a

t least 48” clearance 

to  access the  controls  and  the gas  tank  on  LP  units.  Any guard  or  other  protective 
device removed for servicing must be replaced prior to operating the appliance. 

 

WARNING

 

Never  leave  this  product  on  when  unattended.  Educate  all  persons,  including 
children that may come in contact  with this unit of the danger  of high temperatures 
produced  when  operating,  including  surface  temperatures.  Clothing  and  other 
flammable materials should not be hung from the appliance, or placed on or near the 
appliance. Young children should be carefully supervised when they are in the area 
of the appliance. 

 

IMPORTANT

  It  is  recommended  that  material  such  as  granite,  marble  or  other  dense  stone  be 

kept away from heat and flame due to the risk of cracking. Tropitone will not be held 
responsible for materials damaged due to excessive heat. 

Содержание 401154FTBL

Страница 1: ...sult in property damage Read these installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors or liquids in or near this or any other appliance An LP Liquefied Petroleum tank that is not connected for use shall not be stored in or near this or any other appliance DANGER If you smell gas...

Страница 2: ...ity to ensure this product has been installed in accordance with the local codes applicable and that the end user has been educated on the safe and proper operation of the unit WARNING Tropitone recommends that all gas products installed in the USA and CANADA be serviced and maintained by professionals that are certified by the National Fireplace Institute NFI as a NFI Gas Specialist or by the Woo...

Страница 3: ...for outdoor use only Never install or operate indoors Burning gas both Natural and LP produces fumes which can be dangerous if inhaled Always insure there is proper ventilation when using any fire products DANGER All Fire Tables are designed and intended for outdoor use only Never install or operate indoors Burning gas both Natural and LP produces very high temperatures Always insure all combustib...

Страница 4: ...hould be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necessary It is imperative that control compartment burners and circulating air passageways of the appliance be kept clean DANGER When using glass media in a Fire Table use only approved fire glass and insure that there is only enough to leave the burner holes exposed Applyin...

Страница 5: ...the table is available WARNING The LP Gas tank or cylinder used must comply with the following requirements Use of other tanks or cylinders which do not meet these requirements may create an unsafe condition which could cause injury or death to you or damage to your personal property including the risk of fire or explosion The tank or cylinder used must be 1 Constructed and marked in accordance wi...

Страница 6: ...rer WARNING Inspect the hose and tank connector before each use to insure there is no damage caused by rodents weather or other conditions NEVER use any Fire Table which has any components including the gas hose or gas tank connector damaged in any way If you find any damage turn off the valve on the gas tank and call a licensed repair technician to replace damaged components Replace any damaged i...

Страница 7: ...not install without a regulator which will limit your fuel supply to 5 inches of water column CAUTION Use a joint compound or thread tape approved for the type of gas this appliance is intended to use on all male threads EXCEPT compression threads Never apply thread tape or compound to compression threads Beneath the Burner tray locate the Gas Air Mixer in the plumbing Remove the LP Gas Air Mixer ...

Страница 8: ...al property The deeper your lava rock or glass the more risk of reducing or smothering the flame from the burner Lava Rock Only Application 1 Install your Fire Table per instructions 2 Apply lava rock ONLY deep enough to cover burner no more than 1 2 above burner 3 Blow Out Box Do not cover vents with lava rock leave open Do not allow any rock to block flame opening 4 Blowout Box Do not cover blow...

Страница 9: ...igniter by depressing switch in short bursts until pilot lights 5 Once lit release switch for spark igniter while continuing to depress valve knob for 20 seconds 6 Turn knob counter clockwise left to light main burner NOTE If fails to light rotate knob to center position wait 5 minutes for gas to clear repeat Steps 3 6 If pilot goes out repeat Steps 3 6 7 Once Fire Table has ignited DO NOT leave u...

Страница 10: ...lve x MPT R18VL103 9 LP Tank Connector FPT x 1 20 R18CO113 10 Gas Flex Line 24 x 1 2 R15SP100 11 Compression Fitting 1 8 R15CO104 12 Gas Valve R18VL100 13 Nut Retaining M1 for Gas Valve R02NU501 14 Knob Black for Gas Valve R02MS102 15 Gas Plumbing Support Weldment W401158SGV 16 Elbow 3 8 MPT x 3 8 FPT R15CO100 17 Ignition Switch With Gasket R19SW100 18A Spark Igniter Power Supply Housing Sold as S...

Страница 11: ...less Steel R02NU500 6 Burner Tray Square 18 R15MS301 Burner Tray Round 18 not shown R15MS300 7 Nipple 1 2 Stainless Steel R15CO106 8 1 2 x 3 8 Reducing Bushing R15CO108 9 3 8 LP Gas Air Mixer 40KBTU R18VL104 10 Elbow 3 8 MPT x 3 8 FPT R15CO100 11 3 8 FPT TEE R15CO109 12 3 8 Flare x 1 2 MIPT R18CO107 13 3 8 x 1 8 Reducing Bushing R15CO110 14 Solid Hex Socket Plug W Thread Sealant R02SC443 15 Electr...

Страница 12: ...able has been tested and approved in accordance with ANSI Z21 97 by ICC ES Listing No PMG 1114 Tropitone Furniture Co Inc 5 Marconi Irvine Ca 92618 949 951 2010 www tropitone com 1401 Commerce Blvd Sarasota Fl 34243 Tropitone Furniture Co Inc 2013 12 13 ...