Non
-
woven contamination settings.
The first
is to adjust the height of the sensor in the
cassette, if you lower it, the non
-
woven fabric should
scroll more often (the dirty non
-
woven fabric will be
lighter).
The second
setting is the lower window on the left
side of the cassette, after opening some of the
water does not pass through the fleece. This
solution is important because after our tests we
noticed that after some time of using the roller, the
water becomes too poor, so in this case, you should
not pass 100% of the water through the filter fleece.
Attention!!!
The roller with the motor is not
waterproof, therefore when replacing the dirty
fleece, unplug the motor plug and move the motor
with the dirty fleece to a safe place and remove it
there.
Use and maintenance.
After each used roll:
-
check that the drain strainer in the cassette is
inside and outside free of contamination (e.g. algae,
solid elements such as snail shells / snails, sand,
etc.),
-
check that the rollers are clean,
-
check if the float sensor is working lightly and the
axis on which it moves (in case of problems, remove
the pin, remove the float and wash it thoroughly in
RO water),
-
check for signs of corrosion / tarnish on the sensor,
-
check for moisture from the plugs connecting the
motor and sensor with the controller,
-
check if the fleece is rewound in accordance with
the diagram on the upper cassette,
-
after installing the roller with the motor, pay special
attention to whether it fits well on the handles.
ATTENTION
-
the use of non
-
original reels,
driver, power supply, sensor is associated with
the loss of warranty! The maximum water flow is
8000L / h.
Solving problems
Problem
Cause / Solution
Motor fault (red LED)
Motor fault protection has tripped.
This is due to solid elements that have passed
through the strainer and blocked between the
fleece and the lower rear roller.
Solution - remove the cassette, open the drain
valve to 100% and clean the drain pipes / chim-
ney of small solids (snails, hard algae, etc.)
The engine does not rewind
If the blue or red diode is lit, the controller is
blocked until the controller is restarted (the power
supply is turned off for 1 minute).
The engine only scrolls in the
manual mode.
Check the cables, sensor plug connection with
the controller.
Check that the float sensor is clean and that it
responds to manual lifting
Damp / wet fleece roll
Device mounted too low.
During a power failure to the circulation pump,
the water level in the small sump may rise high
enough to flood the fleece.
The engine is spinning all the
time or it will rewind a clean roll
Check if the float sensor is blocked (dirt, snails),
Check if the sensor plug is properly plugged in,
the controller will rewind the reel for only about 5-
10 seconds and will show an error with a blue
LED.
Rother problems
Please contact the service
Producer:
Tropic creations
33
-
340 Stary Sącz, Popowice 120,
www.tropicreations.com,