GUARANTEES/LIMITATION OF LIABILITY 

Tronair products are warranted to be free of manufacturing or material defects for a period of one year after shipment to the 
original customer. This is solely limited to the repair or replacement of defective components. This warranty does not cover the 
following items: 

a)  Parts required for normal maintenance 
b)  Parts covered by a component manufacturers warranty 
c) 

Replacement parts have a 90-day warranty from date of shipment 

If you have a problem that may require service, contact Tronair immediately. Do not attempt to repair or disassemble a product 
without first contacting Tronair, any action may affect warranty coverage. When you contact Tronair be prepared to provide the 
following information: 

a)  Product Model Number 
b)  Product Serial Number 
c) 

Description of the problem 

If warranty coverage is approved, either replacement parts will be sent or the product will have to be returned to Tronair for 
repairs. If the product is to be returned, a Return Material Authorization (RMA) number will be issued for reference purposes 
on any shipping documents. Failure to obtain a RMA in advance of returning an item will result in a service fee. A decision on 
the extent of warranty coverage on returned products is reserved pending inspection at Tronair. Any shipments to Tronair must 
be shipped freight prepaid. Freight costs on shipments to customers will be paid by Tronair on any warranty claims only. Any 
unauthorized modification of the Tronair products or use of the Tronair products in violation of cautions and warnings in any 
manual (including updates) or safety bulletins published or delivered by Tronair will immediately void any warranty, express or 
implied. 
 
The obligations of Tronair expressly stated herein are in lieu of all other warranties or conditions expressed or implied. 

Any 

unauthorized modification of the Tronair products or use of the Tronair products in violations of cautions and 
warnings in any manual (including updates) or safety bulletins published or delivered by Tronair will immediately

 

void any warranty, express or implied 

and Tronair 

disclaims any and all liability for injury (WITHOUT LIMITATION and 

including DEATH), loss or damage arising from or relating to such misuse

.

 

 

6.0 

APPENDICES 

APPENDIX I 

Instrument Certification Notice 

 

Содержание 14-6895-6000

Страница 1: ...N SERVICE MANUAL Tronair Inc Phone 419 866 6301 800 426 6301 1 Air Cargo Pkwy East Web www tronair com Swanton OH 43558 Email sales tronair com Model 14 6895 6000 Aircraft Strut Pressure Gauge 09 2000...

Страница 2: ...REVISION DATE TEXT AFFECTED OR 09 2000 Original release...

Страница 3: ...AFETY INSTRUCTIONS 1 1 1 GENERAL 1 1 2 SAFETY 1 2 0 OPERATION OF NITROGEN STRUT SERVICE KIT 1 2 1 TRAINING 1 2 2 GENERAL SAFETY REQUIREMENTS 1 2 3 WARNINGS AND CAUTIONS 1 3 0 ASSEMBLY INSTRUCTIONS 2 3...

Страница 4: ...ve that all inspection maintenance testing and servicing of nitrogen system components be done by trained and qualified personnel using approved procedures 2 0 OPERATION OF NITROGEN STRUT SERVICE KIT...

Страница 5: ...efer to Aircraft Maintenance Manual 8 Connect B Hose Coupling to C Nitrogen Charging Valve 9 Open C Nitrogen Charging Valve Refer to Aircraft Maintenance Manual 10 Turn handle clockwise on B Hose Coup...

Страница 6: ...ation RMA number will be issued for reference purposes on any shipping documents Failure to obtain a RMA in advance of returning an item will result in a service fee A decision on the extent of warran...

Страница 7: ...ssure gauge is to be calibrated annually or as required Reference Appendix I Item Part Number Description Qty 1 HC 1862 Gauge 1 500 psi Pressure Calibrated 1 2 H 2153 Boot Gauge 1 3 PC 1074 Cap High P...

Страница 8: ......

Страница 9: ...APPENDIX I Instrument Certification Notice...

Страница 10: ......

Страница 11: ...perform the calibration check The due date for re calibration of the instrument should be based upon the date the instrument was placed in service in your facility Re calibration should be done on a p...