Tronair 14-6895-6000 Скачать руководство пользователя страница 4

Model:  14-6895-6000 

Aircraft Strut Pressure Gauge 

 

09/2000 | Rev. OR 

Page | 1 

 
This product can not be modified without the written approval of Tronair, Inc. Any modifications done without written approval 
voids all warranties and releases Tronair, Inc., it suppliers, distributors, employees, or financial institutions from any liability 
from consequences that may occur. Only Tronair OEM replacement parts shall be used. 
 

1.0 

SAFETY INSTRUCTIONS 

CAUTION! 

It is MANDATORY that this instruction manual be read and understood by all persons operating this high 
pressure Nitrogen strut service kit. 

 
1.1 

GENERAL 

Information presented in this manual and on various labels, tags and plates on the unit pertains to equipment design, 
installation, operation, maintenance and trouble shooting which should be read, understood and followed for the safe and 
effective use of this equipment. 
 
1.2 

SAFETY 

The Operation, Maintenance, and Trouble Shooting of this high pressure Nitrogen strut service kit requires practices and 
procedures which ensure personal operator safety and the safety of others. Therefore, this equipment is to be operated and 
maintained only by qualified persons in accordance with this manual and all applicable local codes. 

NOTE: Safety instructions specifically pertaining to this kit appear throughout this manual highlighted by the signal 
words: WARNING, CAUTION, which identify different levels of hazard. 

WARNING!

  Denote practices which if not carefully followed, could result in 

serious personal injury and/or 

death

CAUTION!

  Denote practices which if not carefully followed, could result in 

minor personal injury or damage to 

this equipment

 
Nitrogen equipment must be kept clean and free from contaminants at all times. It is imperative that all inspection, 
maintenance, testing and servicing of nitrogen system components be done by trained and qualified personnel using approved 
procedures. 
 

2.0 

OPERATION OF NITROGEN STRUT SERVICE KIT 

WARNING 

TO AVOID SERIOUS INJURY, LOSS OF LIMB, AND/OR DEATH: 

1.  DO NOT use high pressure Nitrogen on aircraft components designed for low pressure Nitrogen. 
2.  DO NOT use with Oxygen or gas other than Nitrogen. 
3.  DO NOT exceed 1,500 psi inlet pressure. 
4.  Servicing and maintenance of Nitrogen systems shall be done by only trained and qualified personnel 

using approved procedures. 

 
2.1 

TRAINING 

Read this entire manual prior to operation of the unit. All personnel using this Nitrogen Service Strut Kit should understand and 
follow this manual and receive training. We encourage our customers to call Tronair at 800-426-6301 to discuss any operating 
or testing requirements. 
 
2.2 

GENERAL SAFETY REQUIREMENTS 

Pressures:

  Gasses under pressure are a potential hazard in the form of stored energy. Accidents can occur when this 

energy is improperly handled. Be sure that all equipment used is compatible and designed to control the 
pressures encountered. 

Nitrogen:

 

Nitrogen is chemically stable, non-flammable, and does not support combustion. 

Handling:

 

Nitrogen handling must be done with care. The rapid expansion of Nitrogen gas from a high pressure source to 
an area of low pressure can produce cryogenic temperatures which could cause severe burns. 

 
2.3 

WARNINGS AND CAUTIONS 

WARNING! 

1.  DO NOT use on low pressure Nitrogen system or components. 
2.  If there are any differences between the following instructions and the aircraft maintenance manual, 

the aircraft maintenance manual will take precedence. 

3.  Be sure fill line is secured prior to purging the unit. This will prevent the nose end from whipping 

about if too much Nitrogen is allowed to flow through the unit. 

 

CAUTION! 

Be sure all valves and controls are in the closed (OFF) position. 

Содержание 14-6895-6000

Страница 1: ...N SERVICE MANUAL Tronair Inc Phone 419 866 6301 800 426 6301 1 Air Cargo Pkwy East Web www tronair com Swanton OH 43558 Email sales tronair com Model 14 6895 6000 Aircraft Strut Pressure Gauge 09 2000...

Страница 2: ...REVISION DATE TEXT AFFECTED OR 09 2000 Original release...

Страница 3: ...AFETY INSTRUCTIONS 1 1 1 GENERAL 1 1 2 SAFETY 1 2 0 OPERATION OF NITROGEN STRUT SERVICE KIT 1 2 1 TRAINING 1 2 2 GENERAL SAFETY REQUIREMENTS 1 2 3 WARNINGS AND CAUTIONS 1 3 0 ASSEMBLY INSTRUCTIONS 2 3...

Страница 4: ...ve that all inspection maintenance testing and servicing of nitrogen system components be done by trained and qualified personnel using approved procedures 2 0 OPERATION OF NITROGEN STRUT SERVICE KIT...

Страница 5: ...efer to Aircraft Maintenance Manual 8 Connect B Hose Coupling to C Nitrogen Charging Valve 9 Open C Nitrogen Charging Valve Refer to Aircraft Maintenance Manual 10 Turn handle clockwise on B Hose Coup...

Страница 6: ...ation RMA number will be issued for reference purposes on any shipping documents Failure to obtain a RMA in advance of returning an item will result in a service fee A decision on the extent of warran...

Страница 7: ...ssure gauge is to be calibrated annually or as required Reference Appendix I Item Part Number Description Qty 1 HC 1862 Gauge 1 500 psi Pressure Calibrated 1 2 H 2153 Boot Gauge 1 3 PC 1074 Cap High P...

Страница 8: ......

Страница 9: ...APPENDIX I Instrument Certification Notice...

Страница 10: ......

Страница 11: ...perform the calibration check The due date for re calibration of the instrument should be based upon the date the instrument was placed in service in your facility Re calibration should be done on a p...

Отзывы: