Model: 14-6895-6000
Aircraft Strut Pressure Gauge
09/2000 | Rev. OR
Page | 1
This product can not be modified without the written approval of Tronair, Inc. Any modifications done without written approval
voids all warranties and releases Tronair, Inc., it suppliers, distributors, employees, or financial institutions from any liability
from consequences that may occur. Only Tronair OEM replacement parts shall be used.
1.0
SAFETY INSTRUCTIONS
CAUTION!
It is MANDATORY that this instruction manual be read and understood by all persons operating this high
pressure Nitrogen strut service kit.
1.1
GENERAL
Information presented in this manual and on various labels, tags and plates on the unit pertains to equipment design,
installation, operation, maintenance and trouble shooting which should be read, understood and followed for the safe and
effective use of this equipment.
1.2
SAFETY
The Operation, Maintenance, and Trouble Shooting of this high pressure Nitrogen strut service kit requires practices and
procedures which ensure personal operator safety and the safety of others. Therefore, this equipment is to be operated and
maintained only by qualified persons in accordance with this manual and all applicable local codes.
NOTE: Safety instructions specifically pertaining to this kit appear throughout this manual highlighted by the signal
words: WARNING, CAUTION, which identify different levels of hazard.
WARNING!
Denote practices which if not carefully followed, could result in
serious personal injury and/or
death
.
CAUTION!
Denote practices which if not carefully followed, could result in
minor personal injury or damage to
this equipment
.
Nitrogen equipment must be kept clean and free from contaminants at all times. It is imperative that all inspection,
maintenance, testing and servicing of nitrogen system components be done by trained and qualified personnel using approved
procedures.
2.0
OPERATION OF NITROGEN STRUT SERVICE KIT
WARNING
TO AVOID SERIOUS INJURY, LOSS OF LIMB, AND/OR DEATH:
1. DO NOT use high pressure Nitrogen on aircraft components designed for low pressure Nitrogen.
2. DO NOT use with Oxygen or gas other than Nitrogen.
3. DO NOT exceed 1,500 psi inlet pressure.
4. Servicing and maintenance of Nitrogen systems shall be done by only trained and qualified personnel
using approved procedures.
2.1
TRAINING
Read this entire manual prior to operation of the unit. All personnel using this Nitrogen Service Strut Kit should understand and
follow this manual and receive training. We encourage our customers to call Tronair at 800-426-6301 to discuss any operating
or testing requirements.
2.2
GENERAL SAFETY REQUIREMENTS
Pressures:
Gasses under pressure are a potential hazard in the form of stored energy. Accidents can occur when this
energy is improperly handled. Be sure that all equipment used is compatible and designed to control the
pressures encountered.
Nitrogen:
Nitrogen is chemically stable, non-flammable, and does not support combustion.
Handling:
Nitrogen handling must be done with care. The rapid expansion of Nitrogen gas from a high pressure source to
an area of low pressure can produce cryogenic temperatures which could cause severe burns.
2.3
WARNINGS AND CAUTIONS
WARNING!
1. DO NOT use on low pressure Nitrogen system or components.
2. If there are any differences between the following instructions and the aircraft maintenance manual,
the aircraft maintenance manual will take precedence.
3. Be sure fill line is secured prior to purging the unit. This will prevent the nose end from whipping
about if too much Nitrogen is allowed to flow through the unit.
CAUTION!
Be sure all valves and controls are in the closed (OFF) position.