6.0
TROUBLE SHOOTING
(continued)
6.2
PROCEDURES IN THE EVENT OF MALFUNCTIONS
Follow the steps below in case of malfunctions:
Action Upon Fault Detection
Fault
Description
Condition
Fault Sense
Location
Input
Breaker
DC Output
Contactor
SCR Firing
Enable
(Green)
Input
Voltage
LED
Amber
Warning
LED
Red
Fault
LED
Output
Contact
or LED
Recovery
Notes
None
Normal
Firing Board to
Interface Board
ON
ON
Enabled
ON
OFF
OFF
ON
None
Missing
Phase
Any phase voltage
missing (>5% of
rated voltage)
Firing Board to
Interface Board
Opened
Immediately
Unit Power
Is Off
Unit Power Is
Off
Unit
Power
Is Off
Unit
Power Is
Off
Unit
Power
Is Off
Unit
Power
Is Off
Input Breaker
Must be Cycled
Input
Overvoltage
Secondary AC
Voltage >115% of
max voltage range
Interface Board
Opened
Immediately
Unit Power
Is Off
Unit Power Is
Off
Unit
Power
Is Off
Unit
Power Is
Off
Unit
Power
Is Off
Unit
Power
Is Off
Input Breaker
Must be Cycled
Input Under
Voltage
Primary AC
Voltage <85% of
rated voltage
Interface Board
ON
ON
ON
BLINK
ON
OFF
ON
Automatic when
condition
changes
If input voltage is
to low unit will
brown out
Output Over
Voltage
Output Voltage
>103% of Max of
32.5V at unit
output (> 33.5V)
Interface Board
ON
Opened
After
100ms
Disabled
Immediately
On
BLINK
BLINK
OFF
Input Breaker
Must be Cycled
Output
Under
Voltage
Output <97% of
Min of 24 V at unit
output (< 23.3V)
Interface Board
ON
ON
ON
ON
BLINK
OFF
ON
Automatic when
condition
changes
Output High
Over Current
Output Current >
2100A
Interface Board
ON
Opened
After
100ms
Disabled
Immediately
ON
ON
BLINK
OFF
Input Breaker
Must be Cycled
Transformer
Over-
Temperature
Any/All Core
Temperature
> 180°C
Transformer
Thermal
Switches to
Interface Board
ON
Opened
After
100ms
Disabled
Immediately
ON
ON
ON
OFF
Input Breaker
Must be Cycled
SCR Over-
Temperature
Any/All SCR
Temperature
> 82°C
SCR/Heatsink
Thermal
Switches to
Interface Board
ON
Opened
After
100ms
Disabled
Immediately
ON
OFF
BLINK
OFF
Input Breaker
Must be Cycled
Содержание 112850D0000
Страница 27: ...APPENDIX I Wiring Diagram and Schedule Single Output...
Страница 28: ......
Страница 36: ......
Страница 40: ......
Страница 41: ...APPENDIX II Wiring Diagram and Schedule Dual Output...
Страница 42: ......
Страница 50: ......
Страница 54: ......
Страница 55: ...APPENDIX III Declaration of Conformity...
Страница 56: ......