28.5 VDC Ground Power Unit
Models
112850S0000
112850S0100
112850S0200
112850D0000
112850D0100/AV
112850D0100-A5
112850D0200
112860S0000
112860S0100
112860S0100-A4
112860S0100-A6
112860S0200
112860D0000
112860D0100
112860SD100-A5
112860D0200
112860SD200-A5
06/2013 | Rev. 03
Page | 8
4.4.2
Space Requirements/Dimensions
About 80 cm/32” clearance should be left in front of the unit to provide unimpeded access to the cubicle. Local or general
safety regulations, e.g. escape routes, should also be observed. In no circumstances must the air inlet (around the bottom of
the unit) and the air outlet (around the top of the unit) be covered or obstructed.
4.4.3
Altitude, Temperature &
Humidity
The 28V DC GPU is designed for an installation altitude of up to 1000 meters above mean sea level, an ambient temperature
of -20 to 40
o
C / -4 to +104
o
F and a relative humidity of up to 95%. The optimum temperature is around 68
o
F. Please ensure
that any existing air-conditioning plant meets these conditions and is also able to remove the unit's dissipated heat. Details are
shown in the Technical Data (Section 2). The cooling air must always be free of corrosive agents. You should consult your
Tronair representative if planning an installation above 1000 meters.
4.5
ELECTRICAL CONNECTIONS (POWER)
4.5.1
Cable Entry
The input and output cables are connected in the lower part of the cubicle. The cables can be brought up to the cubicle from
the rear (input cable) and the right (output cable) and led in through end panel of the cubicle. Please refer to table below for
the cable sizes, which must conform to local electrical code.
Cables must be properly gasketed with a screwed gasket fitted with a strain-relief device and sealing ring.
4.5 Electrical connections (power) continued on following page.
Содержание 112850D0000
Страница 27: ...APPENDIX I Wiring Diagram and Schedule Single Output...
Страница 28: ......
Страница 36: ......
Страница 40: ......
Страница 41: ...APPENDIX II Wiring Diagram and Schedule Dual Output...
Страница 42: ......
Страница 50: ......
Страница 54: ......
Страница 55: ...APPENDIX III Declaration of Conformity...
Страница 56: ......