Page | 9
3
Power on
3.1
Visible safety check
Before powering on the TrojanTwo, visibly ensure that no foreign objects are interfering with the print
engine or web-path.
3.2
Power on process
1.
Press the physical power switch on the backside of the TrojanTwo, switching it from 0 to 1.
a.
Turning the main power switch on starts up TrojanControl touch screen and print engine.
For safety reasons the web-path not powered up yet to prevent any unexpected movement
of the label material.
b.
Web state will display ‘Emergency stop’.
2.
Press the physical green start button which can be found on the top of the machine (near the
screen) to initialize (power up) the web path system.
a.
Web state will display ‘Initializing’ during this process.
b.
The initializing process works with or without threaded label material.
3.
The machine is fully functional, when the TrojanTwo tab is visible on the TrojanControl software
and the ‘Web state’ field at status bar is ‘Not calibrated’.
3.3
Installing ink tanks and printhead
3.3.1
Installing ink tanks
The TrojanTwo press uses CMYK ink tanks, each contain 2 liters of ink when opened. Every TrojanTwo ink
tank is QA chip protected ensuring that only genuine Trojanlabel ink tanks can be used.
1.
2.
3.