5
*** The values for the desired settings must be added.
Important: Changes in the settings market with ( * ) for the Selectrix mode
of operation automatically lead to changes in the DCC mode of operation
and versa!
CV
Discription
DCC Value
Factory
Setting
DCC / SX1
SX1 Value
1
* Adress
1 - 127
3 / 03
01 - 99
3
Acceleration delay
0 - 127
8
5
1 - 7
4
Braking delay
0 - 127
6
5
* Maximum speed
1 - 7
5 / 5
1 - 7
17
Extended address (upper part)
CV 29, bit 5 =1
255 / —
—
18
Extended address (lower part)
CV 29, bit 5 =1
255 / —
—
29
bit 0: Travel direction polarity reversal
bit 1: number of speed levels 14 or 28/128
bit 2: DCC Operation with braking Block.
DCC-, Selectrix- and DC power Operation
bit 5: Adress size 7 bit / 14 bit
Value
0 / 1
0 / 2
0 / 4
0 / 32
***
0, 1, 2, 3, 4, 5, 6, 7,
32, 34, 35, 36, 37,
38, 39
6
—
49
* Pulse width for motor control
0 - 3
1 / 2
1 - 4
50
* Rule variant
0 - 3
2 / 3
1 - 4
51
*
bit 0: Motor polarity reversal
bit 1: Headlight polarity reversal
bit 2: Track polarity reversal
0 / 1
0 / 2
0 / 4
***
0 - 7
4 / 4
0 - 7
Содержание BR 232