17
CV
Description
Meaning
Area
Factory
Value
1
Locomotive Address
DCC address for the locomotive
1 - 127
3
2
Starting Voltage
Changes the minimum speed
1 - 63
4
3
Acceleration Time
Value * 0.87 gives the time from a standstill to maximum
speed
1 - 63
8
4
Braking Time
Value * 0.87 gives the time from maximum speed to a
standstill
1 - 63
6
5
Maximum Speed
Locomotive speed at the highest speed level
1 - 63
63
6
Medium Speed
Locomotive speed at the middle speed level
1 - 63
25
8
Default Settings
Return to the factory default settings
8
—
17 + 18
Advanced Address
128 - 9999
0
29
Configuration Register
Caution, very complex!
Total value must be calculated.
Total value = Bit 0 value + Bit 1 value + Bit 2 value ...
0, 1, 2, 3, 4, 5,
6, 7, 16, 17,
18, 19, 20, 21,
22, 23, 32, 33,
34, 35, 36, 37,
38, 39, 48, 49,
50, 51, 52, 53,
54, 55
4
Bit 0: Direction
0 / 1
Bit 1: 14 speed levels / 28 (128) speed levels
0 / 2
Bit 2: Analog operation possible
0 / 4
Bit 4: Motor operation curve determined by
CV 2, 5, 6 / CV 67 - 94
0 / 16
Bit 5: short / long address
0 / 32
49
Adv. Configuration
Bit 0: Lastregelung
0 / 1
0, 1
1
The following CV‘s must not be changed under any circumstances.
7, 33, 34, 35, 36, 37, 38, 39, 40, 60, 61, 62, 63