PoM
Program on the Main; must be supported by the controller
*
The speed levels on the locomotive decoder and on the controller must agree with each other; otherwise,
you may have malfunctions.
***
The values for the desired settings must be added.
CV
Discription
DCC Value
Factory-Set
1
Address
1 - 127
3
2
PoM Minimum Speed
0 - 255
3
3
PoM Acceleration delay
0 - 255
15
4
PoM Braking delay
0 - 255
15
5
PoM Maximum speed
0 - 255
240
8
Factory Reset / Manufacturer Recognition
8
131
13 PoM Functions F1 - F8 in analog operation
0 - 255
0
14 PoM Functions F9 - F15 and lights in analog operation
0 - 255
1
17
Extended address (upper part)
CV 29, Bit 5 =1
192
18
Extended address (lower part)
CV 29, Bit 5 =1
128
19
Multiple Unit Address
0 - 255
0
21 PoM Functions F1 - F8 on Multiple Unit
0 - 255
0
22 PoM Functions F9 - F15 and lights on Multiple Unit
0 - 255
0
29 PoM
Bit 0: Reversing direction
Bit 1: Number of speed levels 14 or 28/128*
Bit 2: DCC operation with braking area
(no analog operation possible)
Bit 5: Address length 7 Bit / 14 Bit
0 / 1
0 / 2
0 / 4
0 / 32
***
0, 1, 2, 3, 4, 5, 6,
7, 32, 34, 35, 36,
37, 38, 39
6
63 PoM Volume
0 - 255
240