11
Important: Changes in the settings market with ( * ) for the Selec-
trix mode of operation automatically lead to changes in the DCC
mode of operation and versa!
CV
Discription
DCC Value
Factory-Set
DCC / SX1
SX1 Value
1
* 7-bit Adress
1 - 127
3 / 1
0 - 111
2
Minimum speed
1 - 15
5 / —
—
3
Acceleration delay
0 - 255
3 / 2
1 - 7
4
Braking delay
0 - 255
3 / 2
5
* Maximum speed
1 - 255
138 / 7 **
1 - 7
7
Version Number
10
60 / —
—
8
Factory Reset / Manufacturer Recognition
8
131 / —
—
17
Extended address (upper part)
CV 29, bit 5 =1
255 / —
—
18
Extended address (lower part)
CV 29, bit 5 =1
255 / —
—
29
bit 0: Travel direction polarity reversal
bit 1: number of speed levels 14 or 28/128
bit 2: DCC Operation with braking Block.
DCC-, Selectrix- and DC power Operation
bit 5: Adress size 7 bit / 14 bit
0 / 1
0 / 2
0 / 4
0 / 32
***
0, 1, 2, 3, 4, 5, 6,
7, 32, 34, 35, 36,
37, 38, 39
6 / —
—
51
* bit 0: Motor polarity reversal
bit 1: Headlight polarity reversal
bit 2: Track polarity reversal
0 / 1
0 / 2
0 / 4
***
0 - 7
0 / 4
0 - 7
—
Stopping Block
—
— / 1
1 oder 2
—
Pulse width for motor control
—
— / 2
1 - 4
—
ABV (Acce) effectiveness
—
— / 1
1 - 2
—
Control variations
—
— / 3
1 - 4
** Higher values do not lead to a further increase in
speed. *** The values for the desired settings must
be added.
Value
Содержание 22135