Triumph A9808081 Скачать руководство пользователя страница 5

5 of 8

6.

Fit the shield and alarm immobiliser to the motorcycle
with the harness pointing to the front of the
motorcycle. Tighten the screws from the fitting kit, to

7 Nm

.

1. Alarm/immobiliser
2. D-shaped bracket
3. Shield
4. Screws

7.

Refit the harness bracket and tighten the bolts to

7 Nm

.

1. Bolts
2. Harness bracket

8.

Refit the fuse box and secure with the new fir-tree
plugs from the fitting kit.

9.

Connect the reed-switch connector to the
alarm/immobiliser harness.

1. Reed-switch connector
2. Alarm/immobiliser connector

10.

Locate the black, twelve pin connector on the main
wiring harness and remove the connector shorting
plug.

1. Connector shortening plug
2. 12 pin connector

Note:

The alarm connector is an unused black coloured
terminal block. The shorting plug is the cover for
this terminal block which is fitted with a double
hoop of black cable.

The shorting plug must be returned to
DATATOOL along with the registration
documentation.

11.

Slide the supplied heat shrink tubing over the
alarm/immobiliser connector. 

Do not shrink the

tubing at this time.

4

3

1

4

2

cfob

1

2

cfoa

1

2

cfof

cckk_2

2

1

Содержание A9808081

Страница 1: ...formance Completely read all of these instructions before commencing the installation of the accessory kit in order to become thoroughly familiar with the kit s features and the installation process T...

Страница 2: ...essory kit to any other Triumph model or to any other manufacturer s motorcycle will affect the performance stability and handling of the motorcycle This may affect the rider s ability to control the...

Страница 3: ...magnet is fitted in the orientation shown below 1 Right hand side panel 2 Reed switch magnet 3 Lower mounting side panel Note Read the warning notices printed on the cleaning wipe packet in the fitti...

Страница 4: ...the bolts and detach the harness bracket from the battery tray 1 Bolts 2 Harness bracket 4 Slide the D shaped bracket over the alarm immobiliser with the open end of the bracket on the left hand side...

Страница 5: ...iliser harness 1 Reed switch connector 2 Alarm immobiliser connector 10 Locate the black twelve pin connector on the main wiring harness and remove the connector shorting plug 1 Connector shortening p...

Страница 6: ...e main wiring harness must be made secure and tamper proof with the heat shrink tubing Before disconnecting the battery ensure that the alarm is set to winter mode as described in the user guide This...

Страница 7: ...evant MIRRC evaluation number as indicated below onto the certificate of installation next to the alarm serial number Caution When fitting the heat shrink tubing take care not to burn any part of the...

Страница 8: ...ycle leading to an accident Warning The motorcycle must not be operated above the legal road speed limit except in closed course conditions Warning Only operate this Triumph motorcycle at high speed i...

Отзывы: