Computer Interface
ADVANCED OPERATION GUIDE
4-7
RS-232C Protocol (C
LP 4
5
24
only)
Parameters of the RS-232C Protocol
A protocol is a set of rules followed by various devices to send or receive
data. The parameters of the RS-232C protocol are stored in the battery-
powered memory of the printer. You can verify these parameters on the
status printout as marked by the following identifications:
•
H1: Baud rate
•
H2: Number of data bits
•
H3: Number of stop bits
•
H4: Parity
•
H5: Protocol logic
•
H6: Buffer-nearly-full threshold
•
H7: Buffer nearly-empty threshold
•
H8: Received data buffer size
The parameters can be changed from the printer operator panel. To
change the value for the serial interface parameters, see
Changing Serial
Interface Parameters (C
LP 4524
only) on page 2-30
.
This following section outlines the parameters and their values you can
select on the operator panel:
H1: Baud rate
The factory setting is 96 (9600 baud).
H2: Number of data bits
7 or 8. The factory setting is 8.
H3: Number of stop bits
1 or 2. The factory setting is 1.
Parameter value
Baud rate
12
1200
24
2400
48
4800
96
9600
19
19200
38
38400
57
57600
11
115200
Содержание CLP 4316
Страница 1: ...Instruction Handbook Advanced CLP 4316 4520 4524 Colour Printer ...
Страница 2: ......
Страница 4: ...Contents ii ADVANCED OPERATION GUIDE ...
Страница 40: ...Using the Operator Panel 2 14 ADVANCED OPERATION GUIDE Menu Map Sample MENU MAP ...
Страница 118: ...Using the Operator Panel 2 92 ADVANCED OPERATION GUIDE ...
Страница 140: ...Computer Interface 4 12 ADVANCED OPERATION GUIDE ...
Страница 146: ...ADVANCED OPERATION GUIDE Index 4 ...
Страница 147: ...A1 ...
Страница 148: ...UTAX GmbH Ohechaussee 235 22848 Norderstedt Germany ...