Zenica

If a side entry is required, the trimplate side will 
have to be cut. With the elbow compression 
fitted on the outlet, temporarily place the 
trimplate into position, then mark the pipe entry 
on the side of the trimplate. Carefully remove 
the appropriate area using a junior hacksaw.
If installing a feed pipe from the back or bottom, 
the centre of the inlet valve to the wall surface is 
20mm 

(fig.9)

.

Note: 

If entry is from the back, the nut of the 

compression fitting will be partially behind the 
surface of the wall. This area MUST be left clear 
when plastering over the pipework in order to 
make the nut accessible for future adjustments.
After choosing the site for the shower, use the 
backplate as a template and mark the two fixing 
holes 

(fig.10)

Drill and plug the wall. An appropriate drill bit 
should be used. If the wall is plasterboard or a 
soft building block, appropriate wall plugs and 
screws should be fitted.
Screw the top fixing screw into position leaving 
the base of the screw head protruding 6mm out 
from the wall.
Hook the backplate over the top screw and fit 
the bottom fixing screw into position.
DO NOT fully tighten the screws at this stage, 
as the fixing holes are elongated to allow for 
out of square adjustment after the plumbing 
connections have been completed.

Fig.10

20

mm

Fig.9

Содержание ZENICA 8.5kW

Страница 1: ...ed person in the sequence of this instruction book IMPORTANT SAFETY ADVICE The shower unit MUST BE switched off at the isolating switch when not in use This is a safety procedure recommended for all e...

Страница 2: ...fitting other than those specified This appliance is intended to be permanently connected to the water mains and not connected by a hose set A suitable double pole isolation switch for supply disconn...

Страница 3: ...mply with Water Regulations Building Regulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS EN 806 2 2 The supply pipe m...

Страница 4: ...erate at a constant rate at your chosen power setting It is the flow rate of the water passing through the heater unit which determines the shower temperature at any given setting the slower the flow...

Страница 5: ...12 Plumbing connections 13 Electrical connections 14 Replacing the cover 15 Commissioning 16 Operating the shower 17 18 Operating functions 19 Instructions for installers and service engineers only 20...

Страница 6: ...element assembly 7 Pressure switch assembly 8 Stabilising valve 9 Terminal block 10 Earth connection 11 Solenoid valve 12 Water inlet 13 Outlet temperature limiter 14 Pressure relief device PRD 15 Tr...

Страница 7: ...ation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main spur socket outlet lighting circu...

Страница 8: ...bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlets in those rooms must...

Страница 9: ...be necessary to select a low power setting to achieve your preferred shower temperature The water supply can be taken from a cold water storage cistern provided there is a minimum head of ten metres a...

Страница 10: ...NOT operate the shower with a damaged or kinked shower hose or a blocked shower head which can cause the PRD to operate When commissioning the shower head must be removed from the flexible hose while...

Страница 11: ...from the back Note Deviations from the designated entry points will invalidate product approvals If a bottom entry has been chosen the cut out pipe entry on the bottom trimplate should be removed fig...

Страница 12: ...n plastering over the pipework in order to make the nut accessible for future adjustments After choosing the site for the shower use the backplate as a template and mark the two fixing holes fig 10 Dr...

Страница 13: ...he connection of the water supply to the inlet of the shower and in compliance with Water Regulations flush out the pipework to remove all swarf and system debris To do this connect a hose to the pipe...

Страница 14: ...cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing through conduit or in trunking or by...

Страница 15: ...ove the cover and position the temperature control knob so that it points to the 1 position fig 14 Position the power selector to the STOP position fig 15 Replace the cover squarely to the backplate a...

Страница 16: ...the electric supply to the shower at the isolating switch The power indicator will light Switch the power selector to the COLD position fig 18 and wait until water starts to flow from the flexible ho...

Страница 17: ...PERATURE Single red symbol is the economy setting for using less power during warmer months Temperature adjustment at this setting is via the temperature control Note If the stated flow rate required...

Страница 18: ...r temperature Turn the temperature control anti clockwise fig 21 this will increase the flow of water through the shower and is indicated by the lower numbers To increase the shower temperature Turn t...

Страница 19: ...overheat temperature is sensed power to the elements will be reduced Water will continue to flow When the temperature has cooled sufficiently power to the elements will be automatically restored to th...

Страница 20: ...e the trimplate and disconnect and remove the compression fitting Also depending on the incoming pipework arrangements and if there is not enough slack in the pipework it may be necessary to remove th...

Страница 21: ...ch wire assembly P07810903 4 Can assembly 8 5kW P07810708 Can assembly 9 5kW P07810709 5 Stabiliser valve assembly P07810800 6 Solenoid valve assembly 83300450 7 Outlet pipe PRD S07811003 8 Pressure R...

Страница 22: ...2 1 Have unit checked Contact Customer Experience 2 1 1 Increase flow rate via temperature control 2 1 2 Blocked shower head clean or replace blocked sprayplate in shower head 2 2 1 Check if stop valv...

Страница 23: ...repairs to the shower should be carried out by a suitably qualified person In the unlikely event of a fault occurring please contact Customer Experience Do not remove the shower from the installation...

Страница 24: ...ners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verif...

Отзывы: