Triton Unichrome Avon Скачать руководство пользователя страница 18

Avon antique thermostatic mixer

16

Содержание Unichrome Avon

Страница 1: ...INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180377A Oct 2002 AVON antique thermostatic built in dual control mixer shower Installation and Operating Instructions...

Страница 2: ...pical installations 4 5 Preparing the mixer valve 6 Siting of shower 6 Installation 7 8 Connecting the supply pipes 8 Fitting the fixed head 9 Fitting the face plate and controls 10 Commissioning 11 O...

Страница 3: ...on flow rate of 3 litres per minute At flow rates between 3 and 8 litres per minute the appliance must be capable of raising the water temperature to a minimum of 52 C Water temperature at the inlet t...

Страница 4: ...Mixer valve 2 Face plate 3 On off flow lever 4 Threaded trim ring 5 Temperature control 6 Temperature control trim 7 Ceramic cap flow 8 Ceramic cap temp 9 Screws Tiling shroud Sprayhead and arm Flow...

Страница 5: ...pressure reducing valve fitted in the cold mains supply pipework can provide nominally equal pressures at the shower mixer The pipework should be installed such that the flow is not significantly aff...

Страница 6: ...lled within the boiler check with manufacturer and is in addition to the normally larger central heating expansion vessel The layout and sizing of pipework MUST be such that nominally equal inlet supp...

Страница 7: ...anufacturer d Gravity fed systems fig 5 The shower control MUST be fed from a cold water cistern and hot water cylinder providing nominally equal pressures There must be a minimum of one metre head of...

Страница 8: ...he valve prior to installation to allow for final adjustment of the valve position SITING OF THE SHOWER WARNING THE SHOWER MUST NOT BE POSITIONED WHERE IT WILL BE SUBJECT TO FREEZING CONDITIONS Refer...

Страница 9: ...nob and trim ring b Installation in a solid wall Decide on the shower position and determine whether the hot and cold water supplies will enter the shower from the top falling or bottom rising or rear...

Страница 10: ...rear Mark the route of the incoming and outgoing pipework Using the face plate as a template mark the two hole positions for the control knobs Cut the panel or cubicle as required Route the pipework...

Страница 11: ...oud Note that if the tiles are accurately cut to match the profile of the shroud then the face plate will seal around the hole in the tiles and the valve unit will be able to be serviced without the n...

Страница 12: ...temporarily onto the splined adaptor fig 14 DO NOT secure with the screw or fit the finishing cap yet until after the commissioning procedure On off flow lever assembly Insert the rubber trim seal int...

Страница 13: ...red maximum showering temperature is reached The mixer valve is factory set to provide a maximum outlet temperature of 40 C but this should be checked on site to ensure the setting has not been altere...

Страница 14: ...and the two controls Remove the threaded trim ring then pull the face plate away from the wall Unscrew the filter cap fig 17 on each inlet and remove the filter Wash the filter thoroughly under runnin...

Страница 15: ...60 4 Ceramic head works 83307220 5 Stop cock 83307230 6 Non return valve 83307240 7 Connection kit 83307170 8 Thermostatic cartridge 83307250 9 Temperature trim ring Chrome 83307260 Gold 83307630 10 T...

Страница 16: ...act Triton Customer Service 1 5 1 Reduce the simultaneous demand from the supply 2 1 1 Refer to commissioning section 2 2 1 Turn the temperature control clockwise 2 3 1 Turn the temperature control cl...

Страница 17: ...nded 6 1 Running pressure in excess of maximum recommended 7 1 Pipework not flushed before connecting the unit seals damaged 5 1 1 Fit a pressure reducing valve 6 1 1 Fit a pressure reducing valve 7 1...

Страница 18: ...Avon antique thermostatic mixer 16...