13
NOTE:
The elements on UK models are to
240V specification and will give a lower kW
rating if the voltage supply is below 240V.
7
Continued
SECTION
• (fig.12)
shows a schematic wiring diagram.
IMPORTANT:
When connecting the cable fully
tighten the terminal block screws and make sure
that no cable insulation is trapped under the
screws. Loose connections can result in cable
overheating.
NOTE:
The supply cable earth conductor must
be sleeved. The outer sheath of the supply cable
must be stripped back to the minimum.
• The use of connections within the unit or
other points in the shower circuit to supply
power to other equipment i.e. extractor fans,
pumps etc. will invalidate the guarantee.
•
DO NOT
switch on the electricity supply
until the shower cover has been fitted.
FITTING THE COVER
Figures
13, 14, 15
and
16
(on page 14) show
the correct control knob position when replacing
the cover.
• Check to ensure that the wiring is not
trapped and replace the cover squarely to
the backplate and guide into position so that
the knobs locate correctly into the splined
spindles.
•
Should any difficulty arise, recheck the
points above.
• While applying slight pressure to the cover,
secure in position with the retaining screws.
•
Fit the Riser Rail and Kit
(see kit
instructions).
Installation
- FITTING THE COVER
8
check list
SECTION
2
3
4
5
6
L
N
E
inlet
outlet
1
3
6
Fig.12
1.
3 way terminal block
2.
Start/Stop Microswitch
3.
Power selector Microswitch
4.
Solenoid valve
5.
Thermal cut-out (main)
6.
Element
WARNING
COVER RETAINING SCREWS
ONLY
the
SUPPLIED SCREWS
should be
used. The use of none supplied screws
WILL
invalidate product specifications & warranty.