Triton Novel SR Скачать руководство пользователя страница 6

Power Shower

6

Fig.1

  7.  PCB / power supply
  8.  Setting ring
  9.  Temperature control valve
 10.  Solenoid outlet
 11.  Cover Connector
              Cover outline

MAIN COMPONENTS

  1.  Cover screw fixing
  2.  Motor retaining bracket
  3.  Wall fixing holes
  4.  Pipe inlets – swing 
    (contains single check valves)
  5.  Filter cover
  6. Pump

4

5

2

6

7

`

1

8

3

3

3

10

3

1

9

11

Содержание Novel SR

Страница 1: ...ower Shower IMPORTANT SAFETY ADVICE The shower unit MUST BE switched off at the isolating switch when not in use This is a safety procedure recommended for all electrical appliances The showerhead and hose supplied with this product are a safety critical part of your shower Failure to use genuine Triton parts may cause injury and invalidate your guarantee ...

Страница 2: ...r outlet flow The outlet must not be connected to any tap or fitting other than those specified This appliance must not be connected to the water mains supply and not connected by a hose set Minimum inlet pressure 0 075 metres 0 75kPa 0 0075 bar Maximum inlet pressure 10 metres 100kPa 1 bar This book contains all the necessary fitting and operating instructions for your power shower Care taken dur...

Страница 3: ...d water supply must be taken directly from the cold water cistern to the shower This draw off must be on the opposite side of the cistern to the float operated valve to reduce the risk of air entering the unit 2 11 The action of the pump is to increase the flow rate If the supply pipework cannot handle the resulting flow rate then 2 11 1 The anticipated flow rate may not be achieved 2 11 2 Air may...

Страница 4: ...WER 10 PLUMBING CONNECTIONS 11 12 FITTING THE SHOWER TO THE WALL 12 13 ELECTRICAL CONNECTIONS 14 COMMISSIONING 15 16 TEMPERATURE CONTROL SET UP 17 OPERATING THE SHOWER 18 CLEANING THE FILTERS 19 FAULT FINDING 20 21 SPARE PARTS 22 GUARANTEE SERVICE POLICY ETC REAR COVER To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service ...

Страница 5: ...e 65 C A stored water temperature of 60 C is considered sufficient to meet all normal requirements and will minimise the effects of scale in hard water areas Temperature Control To obtain the maximum performance this unit should be installed operated and maintained as instructed in this book Optimum performance is achieved with water supplies of 15 C cold and 60 C hot and with nominally equal pres...

Страница 6: ...mperature control valve 10 Solenoid outlet 11 Cover Connector Cover outline MAIN COMPONENTS 1 Cover screw fixing 2 Motor retaining bracket 3 Wall fixing holes 4 Pipe inlets swing contains single check valves 5 Filter cover 6 Pump 4 5 2 6 7 1 8 3 3 3 10 3 1 9 11 ...

Страница 7: ...er Shower 7 Entry Points Key H C Water Entry Points Cable Entry Points Rear Entry Rear Entry Swivel water inlet feature for top or bottom connection H C H C H C H C H 292mm W 219mm D 115mm Dimensions Fig 2 ...

Страница 8: ...linder Drain valve Other hot water draw offs Alternative connection Shower unit Ring main 25mm min Isolating spur 3A fused outside bathroom Dedicated cold supply 10m max 75mm min Isolating valves Fig 3b Incorrect Connections Diagrammatic view not to scale Fig 3a Recommended Installation Diagrammatic view not to scale ...

Страница 9: ...3a shows a recommended installation where the hot water supply for the shower is made via a tee connection on the underside of the horizontal section of pipework from the cylinder Alternatively the connection can be taken from the hot supply pipe to other outlets as long as it is the first draw off below the ventilation pipe tee IMPORTANT Failure to conform to Fig 3a can allow air ingress into the...

Страница 10: ...rhead and riser rail can be positioned either side of the shower unit Note Water Regulations require the showerhead be constrained by a fixed or sliding attachment so that it can only discharge water at a point not less than 25mm above the spill over level of the relevant bath shower tray or other fixed appliance The use of the supplied soap dish will in most cases meet this requirement but if the...

Страница 11: ...dicated cold water supply must be taken directly from the cold water cistern to the shower This draw off must be positioned 25mm below the cold feed connection to the hot water cylinder on the opposite side of the cistern to the float operated valve see fig 3a This minimises air ingress into the pipework Plumbing options other than those outlined in these fitting instructions could impair the perf...

Страница 12: ...fixed to the wall so that it cannot be moved or removed without the aid of a tool Note The pipe inlets contain filters These should be periodically removed and cleaned in order to maintain the performance of the shower See section Cleaning the Filters on how to access them IMPORTANT The inlets contain check valves Before completing the connection of the water supplies to the shower flush out the p...

Страница 13: ...l type i e brick plasterboard Note If fitting rising supplies to the unit ensure debris does not enter the pipes when drilling the wall Offer the backplate unit back up to the completed pipework and again manoeuvre so that the end of the pipes fully enter into the inlet fittings Check the backplate is square and the fixing holes are aligned and secure to the wall Once the backplate is secured add ...

Страница 14: ...rea of the wall fixings and connect to the terminal block fig 17 as follows Neutral cable to terminal marked N Live cable to terminal marked L Earth cable If present to terminal marked E IMPORTANT Make sure wires are within the terminal block clamps and not undernreath Fully tighten the terminal block screws and check that no cable insulation is trapped under the screws or clamps Note Fuses do not...

Страница 15: ... sure the outlet of the hose is directed to waste and the isolating valves controlling the water supply to the unit are fully open On the PCB ensure the dip switch is in the ON position fig 18 to allow commissioning without pump operation Fit the cover assembly attaching the 8 way connector leads to the 8 way pins on the PCB fig 19 this will only fit one way DO NOT let the cover dangle by the lead...

Страница 16: ...ssary If rear entry has been used then seal around pipes with mastic to prevent the possibility of water entering the wall cavity DO NOT use plaster as this could cause difficulties if maintenance is required at a later date Set up Procedure On the PCB position the dip switch to the OFF position to allow pump operation fig 22 Check the maximum temperature stop is still in position at 12 O clock fi...

Страница 17: ...lockwise fig 25 until desired temperature is reached making sure this is a settled temperature from handset use the temperature knob to move spindle This will now become your new maximum temperature stop setting Do not move the spindle again at this point Fit the temperature control knob with the override button just to the right of vertical position ensuring the travel stop engages with the maxim...

Страница 18: ... to be used again immediately As a safety feature the temperature control has a built in stop to prevent accidentally exceeding your highest desired temperature If adjustment is required see section Temperature Control Set up To override this stop press the button fig 26 while the control is up against the stop and turn the control anti clockwise to the higher temperature settings To return to the...

Страница 19: ...g the O rings are back in position Secure filter cap with the retaining screw Make sure the valve spindle is correctly aligned See section Temperature Control Set Up Offer the cover to the unit and reattach the connector lead to the PCB Ensure the wires are clear of the cover Secure the cover with the top and bottom fixing screws Refit the temperature knob with the override button just to the righ...

Страница 20: ...ervice 2 5 1 Turn shower off Consult a competent plumber or contact Customer Service 3 1 1 Blown fuse Check supply Renew fuse If it fails again consult a competent electrician 3 1 2 Power cut Check other appliances and if necessary contact local Electricity Supply Co 3 2 1 Consult a competent electrician or contact Customer Service 3 3 1 Thermal protection on motor has operated Allow appliance to ...

Страница 21: ...nd replace 6 1 1 Call Customer Service 6 2 1 Call Customer Service 7 1 1 Call Customer Service 7 2 1 Replace pump 4 Water does not flow or is reduced 5 Cross flow of hot and cold water into system 6 Water dripping from showerhead when turned off 7 Pump is noisy 4 1 Water supplies cut off 4 2 Shower blocked or air in the system 4 3 Showerhead blocked 4 4 Blocked filters 5 1 Dirt debris in check val...

Страница 22: ...ke back scheme DTS registration number 9659 All our electric products are labelled accordingly with the crossed out wheeled bin symbol This indicates for disposal purposes at end of life that these products must be taken to a recognised collection points such as local authority sites local recycling centres this will be free of any charges Do not return to Triton Showers To purchase a genuine Trit...

Страница 23: ...Power Shower 23 ...

Страница 24: ...r Service Spares Department on 01 628 6711 Payment should be made by credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information contained in the user guide Triton cann...