CAUTION! KEEP IN MIND THE RECOVERY (PRODUCT/
REJECTION) SUGGESTED BY YOUR DEALER BASED
ON WATER ANALYSIS DONE.
CAUTION! WASTE VALVE SHOULD NEVER BE
COMPLETELY SHUT.
WARNING! DO NOT EXCEED THE RECOMMENDED
PRESSURE OF MEMBRANE PARAMETERS.
7. RECIRCULATION VALVE:
This valve is located on the upper
front panel. Its propose is to adjust the amount of waste water
that recirculates into the feed water of the system. It is used to
refine and adjust pump pressure. You should be cautious of
the incoming waters charecteristics, not to exceed the rate
of salinization with imbedded tendency such as calcium,
magnesium, silica and avoid membrane fouling problems.
8. PRE-FILTER:
This filter is a 5-micron pre-filter. It is used to
remove any particles that may have passed through pre-
treatment or released by pretreatment materials. After this
sediment filter there is a second filtration stage, a 5-micron
carbon block filter. If the cartridge is dirty it can cause
pressure loss.
9. HIGH PRESSURE PUMP:
This creates high pressure for
proper Reverse Osmosis operation. The pressure of the system
is adjusted by the waste valve and the recirculation valve.
Additionally, if necessary, this pump has a pressure increase
screw at the top of the pump, the pressure increases by turning
the screw to the right and the pressure decreases by loosening
the screw to the left. This screw is already adjusted when the
system has been factory tested.
CAUTION! NEVER USE THE PUMP WITHOUT WATER.
10. CONTROL BOX:
The Reverse Osmosis system is designed to
be automatically operated by an electronic controller. The EC-100
controller monitors the operation parameters of the system and
sends continuous information to the screen.
In addition, the system has security features integrated into its
design to protect components and continuously monitor the
quality of product water produced.
Pump Motor overload
- Amperage surges are addressed by a
thermal relay located on the motor contactor installed for the
high-pressure pump.
Start Timer delay
- The start delay or pump start delay is
10 seconds. This helps detect potential problems with the
solenoid valve or voltage spikes.
Low Pressure Switch
- Protects the high-pressure pump to not
operate without water, detects no or low pressure in the system
and immediately shuts down the system and sends an alarm to
the screen. Low pressure switch is activated at 10 PSI.
Product Water Level Connections in the Storage Tank
-
Option A: When using an atmospheric tank, a High Level Switch
( provided with the system ) is used. Option B: When using a
pressurized tank it is required to use a Cut Switch as if it were a
stop and start signal of a jet pump, it is recommended to use a
range of 20-40 psi. (See page 15)
Product Water Quality Sensor
- The system has an integrated
TDS sensor for monitoring water quality and is constantly
visible on the control screen. The TDS sensor can be read in PPM
and can be set to trigger an alarm if water quality is abnormal.
11. INLET SOLENOID VALVE:
Normally closed solenoid valve
(
NC
). This valve is located on the feed side of the pressure pump.
Its purpose is to stop the water supply when the unit is not
operating. If the power fails, this valve will close.
NOTICE: NEVER USE THIS FILTER AS THE ONLY WAY
OF PRE-TREATMENT FOR YOUR REVERSE
OSMOSIS SYSTEM.