Bewitch
Power on indicator
When the electricity supply to the shower is
switched on at the isolating switch, the power
indicator will light.
Low pressure indicator
If this indicator lights then the water pressure
has fallen below the minimum required for
correct operation of the shower, resulting in the
low pressure cut-out operating. This switches off
power to the heating elements preventing any
undue temperature rises (water will continue to
flow). Power will automatically be restored when
adequate water pressure returns.
Selector mode indicators
Next to each control button there is an indicator
that lights when the button is pressed, visually
indicating which shower mode is in operation.
Phased shutdown
In use, when the ‘Stop’ button is pressed,
power is switched off to the elements. Water
will continue to flow for a few seconds, flushing
out any remaining hot water. This makes sure
the next immediate user will not receive a slug
of hot water if standing under the showerhead
when starting the shower.
temperature limiter
During normal operation if an overheat
temperature is sensed, power to the elements
will be reduced. Water will continue to flow.
When the temperature has cooled sufficiently,
power to the elements will be automatically
restored to the previous setting at the time of
interruption.
Safety cut-out
The unit is fitted with a non-resettable
thermal cut-out safety device. In the event of
abnormal operation which could cause unsafe
temperatures within the unit, the device will
disconnect the heating elements. It will require a
visit from a qualified engineer to determine the
nature of the fault and replace the safety device,
once the unit has been repaired.
Low pressure