background image

I

NSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

2180404A    August 2004

Installation and

operating

instructions

AS2000XT

Thermostatic

power shower 

Содержание AS2000XT

Страница 1: ...INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180404A August 2004 Installation and operating instructions AS2000XT Thermostatic power shower...

Страница 2: ...ioning 12 14 Temperature control spindle setting 14 Fitting the riser rail 15 16 Operating the shower 17 18 Adjusting the maximum temperature stop 18 Adjusting the sprayhead 19 Cleaning 20 Cleaning th...

Страница 3: ...hieved 1 9 2 Air may be drawn into the hot supply from the vent pipe causing spluttering and temperature fluctuations at the sprayhead 1 10 A high level hot feed pipe run will result in air locking an...

Страница 4: ...duty cycle SAFETY WARNINGS a Do not insert fingers into the push in inlet fittings Doing so could cause injury b Under no circumstances must this product be connected to mains cold or hot water suppli...

Страница 5: ...rmance specification as below for the unit is achieved with a blend set between 35 C 40 C and supplies of 15 C cold and 65 C hot with nominally equal pressures 1 The blended water temperature is maint...

Страница 6: ...e tee Isolating valve Hot supply Hot water cylinder Drain valve Other hot water draw offs Alternative connection Shower unit Ring main 25mm min Isolating spur 3A fused outside bathroom Dedicated cold...

Страница 7: ...g not used High level hot feed Hot feed connection above vent tee Cold supply from cylinder feed Drain valve Hot water cylinder Other cold draw offs from shower supply Supply taken from mains Mains su...

Страница 8: ...Position the shower and sprayhead on the wall so that all controls can be comfortably reached when using the shower The sprayhead and riser rail can be positioned either side of the shower unit Note W...

Страница 9: ...ECTIONS Plumbing to be carried out before wiring Note The outlet of the shower must not be connected to anything other than the hose and sprayhead supplied DO NOT use jointing compounds on any pipe fi...

Страница 10: ...t to the top pipe inlet must be cut out including the top left wall fixing hole When fitting the elbows to incoming pipework ensure the elbow collets are fully engaged with the pipe Dimensions are sho...

Страница 11: ...ould be left in position if bottom pipe entry is required For top or rear pipe entry the two plugs MUST be removed and refitted into the bottom pipe inlets Failure to fit the blanking plugs will resul...

Страница 12: ...positions for wall fixing holes using backplate as template fig 17 Note that four fixing holes are provided but using only two should be adequate for most site conditions Using the pipe removal tool s...

Страница 13: ...o cable insulation is trapped under the screws Note The supply cable earth conductor must be sleeved The earth continuity conductor of the electrical installation must be effectively connected electri...

Страница 14: ...nto the spindle fig 20 On the PCB position the commissioning link on the middle two pins fig 21 Switch on electric supply at isolating switch Water will begin to flow under gravity pressure In order t...

Страница 15: ...from the PCB fig 23 and store safely for future use Offer the cover to the unit Make sure the Start Stop button is in the off position flush with the cover Attached to the flow control potentiometer i...

Страница 16: ...or normal operation TEMPERATURE CONTROL SPINDLE SETTING Occasionally the spindle may need adjusting when the temperature control and cover are removed from the unit To reset the spindle to its correct...

Страница 17: ...31 Using the brackets as templates mark two upper holes and two lower holes Note there are four provisions for screws per bracket select the two most suitable for your requirements Make sure the rail...

Страница 18: ...d the flexible hose through the soap dish aperture fig 34 so the dish acts as a retaining ring Water Regulations Screw the flexible hose to the shower outlet and sprayhead checking the supplied washer...

Страница 19: ...emperature control has a built in stop to prevent you accidentally exceeding your highest desired temperature If adjustment is required see section Adjusting the maximum temperature stop To override t...

Страница 20: ...ol to setting 5 on the temperature scale Remove the cover trim to gain access to the retaining screw Unscrew the retaining screw and pull off the temperature control fig 41 Carefully pull off the maxi...

Страница 21: ...a t u r e s e t t i n g 19 ADJUSTING THE SPRAYHEAD Five sprayhead patterns are available fig 43 Adjustment is by turning the bezel on the sprayhead in either direction until the desired pattern is obt...

Страница 22: ...top Hold the cartridge firmly and continue to twist anti clockwise Having loosened the sprayplate sufficiently it can be unscrewed and removed completely Clean the sprayplate with a suitable brush or...

Страница 23: ...tom entry is used Pull off the filter cover Carefully hook out the filters together with O rings Thoroughly clean the filters and replace ensuring the O rings are in position Refit the filter cover an...

Страница 24: ...astic inlet elbow plug x1 7052140 Maximum temperature stop 7052186 Pipe removing tool 7052144 Pipe trim 7052146 Wire kit 83305340 10 Cover c w knob potentiometer P09430600 Rear entry elbow 22008180 Te...

Страница 25: ...Description Part No 11 5 mode sprayhead 22011070 12 Brackets pair 22010430 13 Cover trims pair 22010440 14 Riser rail chrome 22010750 15 Sprayhead holder 22010460 16 Soap dish 22010470 17 Flexible hos...

Страница 26: ...supply Renew fuse If it fails again consult a competent electrician 3 1 2 Power cut Check other appliances and if necessary contact local Electricity Supply Co 3 2 1 Consult a competent electrician or...

Страница 27: ...ck valves Clean and replace 6 1 1 Call Customer Service 6 2 1 Call Customer Service 7 1 1 Call Customer Service 7 2 1 Replace pump 8 1 1 Fit blanking plugs into unused inlets 4 Water does not flow or...

Страница 28: ...quoting credit card MasterCard or Visa details 3 By website order www tritonshowers co uk Triton Plc Shepperton Park Caldwell Road Nuneaton Warwickshire CV11 4NR Customer Service 024 7637 2222 Scotti...

Отзывы: